8. Clearing locking authorisations

If two antennas are being used, the individual steps for clearing the locking
authorisations must be carried out consistently on the same antenna.

8.1 Clearing the locking authorisation of an individual user key

Prerequisites:
x
1. Hold the clearing key card in front of the
antenna.
Acoustic signal is heard. LED flashes red for
max. 5 seconds.

8.2 Clearing locking authorisations for all user keys

If a user key is lost, the locking authorisations of all user keys must be cleared. The locking
authorisations can then be granted again
Prerequisites:
x
1. Hold the clearing key card in front of the
antenna.
Acoustic signal is heard. LED flashes red for
max. 5 seconds.
Tag-it ™ISO
x
Clearing key card
5 s
Tag-it ™ISO
x
Clearing key card
5 s
2. Hold the user key in front of the antenna during
this 5-second period.
Acoustic signal is heard. LED briefly
illuminates red. Locking authorisation of this
user key is cleared.
7. Programming user keys.
Tag-it ™ISO
2. Hold the programming key card in front of the
antenna during the 5-second period.
Acoustic signal is heard. LED briefly
illuminates red. The locking authorisations
of all user keys are cleared.
User key with locking