3.2 Technical data
FT 200 / FT 200 CAP furniture terminal
Feature
Power supply
Current consumption
Ambient temperature
Relative humidity
Antenna FAN 200
Feature
Degree of protection
Read range
Transponder technology
Environment
Minimum distance between two
antennas
EFL 3 DG2 / EFL 3C DG2 furniture lock
Feature
Voltage supply
Continuous current consumption
Current consumption unlocking/
locking
Tensile load
Operating temperature
Relative humidity
Power supply unit PS 4
Feature
Input voltage
Output voltage
Mains lead length
Output cable length
Relative humidity
Operating temperature
Approvals
Value
12 V, ±20%
75–850 mA
0–55°C
10–95% not condensed
Value
IP 67
≤25 mm
Tag-It, Mifare Classic EV1, Mifare DESFire EV1 and EV2
Not suitable for installation:
• in metal
• in metal-coated furniture
• behind mirrored surfaces
250 mm
Value
12 V DC
≤10 mA
100 mA/40 ms
1000 N
0-50° C
0–95%, not condensed
Value
100–240 V AC, 50–60 Hz
12 V DC, regulated
2,100 mm
1,350 mm
0–95%, not condensed
0–45° C
MM, CE, FCC, UL, Level VI, FWGB, Approved Medical Device
27