Palazzetti ECOFIRE IDRO Notice D'installation page 38

Masquer les pouces Voir aussi pour ECOFIRE IDRO:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.5.1 Discharge through roof using a traditional
chimney
be made in accordance with standards UNI 10683
- EN 1856-1-2 - EN 1857 - EN 1443 - EN 13384-
1-3 - EN 12391-1 both as regards the dimensions
and the construction materials used.
DAMAGED chimneys made from unsuitable
material (asbestos cement, galvanised steel,
etc.... with a rough and porous inside surface) are
prohibited by law and affect proper stove operation.
chimney (Fig. 5.8) as long as you make sure on the
state of maintenance of the chimney.
For larger chimneys, suitably insulated steel
pipes need to be inserted on the inside (diameter
according to the length) (Fig. 5.9).
Makes sure connections to brick chimneys are
suitably sealed.
available on the market.
1) Vermiculite and/or rock wool.
2) Steel pipes.
3) Closure panel.
38/13
INSTALLATION
cod. 004772532 - 07/2018 - Palazzetti - PN - Italy
A) Chimney pot with wind protection
B) Seal
C) Inspection
2
Fig. 5.8
1
3
Fig. 5.9

Publicité

Table des Matières
loading

Table des Matières