Door opening time adjustment
This parameter, adjustable between 1 and 99, represents the time in seconds that the
door release remains activated after an activated card has been shown.
¡Beep!
¡Beep!
¡Beep!
1. Show the MASTER card
(three times).
The indicators will display
the"door release activation
time configuration mode"
setting.
Adjusting open door time
This parameter, adjustable between 0 and 99, represents the time in seconds after
which the reader's built-in sonic alarm will start to sound, while the door stays open.
Installation of a magnetic door sensor is required. See diagram.
Initially, this function is disabled (value 0). To enable it, you must follow these steps:
¡Beep!
¡Beep!
¡Beep!
¡Beep!
1. Show the MASTER card
(four times).
The indicators will dis-
play the "door open time
configuration mode."
NOTE:
The first time that a card is shown disables this options. The other ones enable the
system and increase the time in seconds.
¡Beep!
¡Beep!
2. Show any card (except the
MASTER) as many times as
seconds to be set for door
release activation.
One time: one second.
Two times: two seconds...
¡Beep!
¡Beep!
2. Show any card (except the
MASTER) as many times as
seconds to be set for open
door detection.
See note below.
¡Beep!
¡Beep!
3. Show MASTER card at the end,
until indicators display "normal
mode."
¡Beep!
3. Again show the MASTER card
at the end, until indicators
display "normal mode."
Pag 7