PERFORMANCE DATA
Models R800 and R1100
Important Notice: Read this performance data and compare
the capabilities of this system with your actual water treatment
needs. It is recommended that, before installing a water
treatment system, you have your water supply tested to
determine your actual water treatment needs.
This system has been tested according to ANSI/NSF 42 and 53
for reduction of the substances listed below. The concentration
of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in ANSI/NSF 42
and 53.
800R
Influent Challenge
Permissible
Substance
Concentration
Product Water
Standard 42
Chlorine
2.0 mg/L ± 10%
Test Conditions
Flow Rate
= 0.75 gpm
Filter Capacity
= 2500 gallons (9460 L)
Inlet Pressure
= 60 psi (4.1 bar)
pH
= 7.5±1
Temperature
= 68°F ± 5°F (20°C ± 2.5°C)
1100R
Influent Challenge
Permissible
Substance
Concentration
Product Water
Standard 42
Chlorine
2.0 mg/L ± 10%
Particulates
at least 10,000
(0.5–<1m) Class I
particles/mL
Standard 53
Minimum
Cysts
50,000/L
Turbidity
11 mg/L±1 NTU
Lead (pH 6.5)
0.15 mg/L ± 10%
0.010 mg/L
Lead (pH 8.5)
0.15 mg/L ± 10%
0.010 mg/L
0.002 mg/L
Lindane
0.0002 mg/L
± 10%
0.009 mg/L
Atrazine
0.003 mg/L
± 10%
Test Conditions
Flow Rate
= 0.5 gpm
Filter Capacity
= 500 gallons (1892 L) or 6 months
† Based on the use of microspheres or Cryptosporidiuim parvum oocysts
Testing was performed under standard laboratory conditions, actual performance may vary.
Operating Requirements
Pressure
= 30-125 psi (2.1–8.62 bar)
Temperature
= 40-100°F (4.4–37.8°C)
Turbidity
= 5 NTU Max.
Maximum
Reduction
Requirements
Average
≥50%
87.8%
Maximum
Reduction
Requirements
Minimum
Average
≥50%
99%
≥85%
99.8
99.95%
99.99%
99.99%
0.5 NTU
99.6%
99.97%
99.3%
99.3%
98%
98.6%
97.5%
97.5%
97.7%
97.7%
WARNING
Do not use with water that is microbiologically
unsafe or unknown quality without adequate disinfection before
or after the system. Systems certified for cyst reduction may be
used on disinfected waters that may contain filterable cysts.
NOTE: Filter must be maintained according to manufacturer's
recommendations, including replacement of filter cartridges. The
contaminants or other substances removed or reduced by this
water treatment device are not necessarily in your water.
REPLACEMENT PARTS
1
155901
800R Filter Cartridge
2
155785
1100R Filter Cartridge
3
144842
Head Assembly
4
144846
Hardware Kit
5
150620
FVK-100 Flush Valve Kit
2
1
For replacement parts contact your local OMNIFILTER retailer or
call OMNIFILTER Customer Service at 800.937.6664.
3
5
4
• 5 •