Télécharger Imprimer la page

Pentair OMNIFILTER R800 Instructions D'installation page 4

Publicité

Les langues disponibles

Les langues disponibles

FILTER CARTRIDGE REPLACEMENT
NOTE: We recommend that you change the 1100R cartridge
every 6 months and the 800R cartridge every 12 months, or
when you notice a change in taste, odor, or flow of the water
being filtered.
A)
Relieve pressure by turning off water supply to the filter
and dispense water from water dispenser or T-flush valve
until water flow stops. Place bucket or towel under the
system to catch any water drips.
(1) Twist cartridge away from the locked position to the
unlock position and (2) remove cartridge.
A
2
B)
(1) Line up arrow on replacement cartridge with the
unlocked position on head and insert cartridge and (2)
turn arrow to locked position.
B
1
C)
Turn on water and check for leaks. If leaks are found, see
Troubleshooting section in manual, or call OMNIFILTER
Customer Service at 800.937.6664.
NOTE: A water cartridge may contain carbon fines (very
fine black powder). This will be released during your initial
flushing.
D)
Flush water through filter for 5 minutes to remove carbon
fines. Check for leaks again before leaving installation.
• 4 •
TROUBLESHOOTING
Leaks between head and cartridge
1.
Turn off the water supply to the filter and dispense water
from refrigerator door or T-flush valve until water flow stops.
2.
Remove cartridge and inspect o-rings to make sure they are
in place and clean.
3.
Install cartridge and turn on water supply. If it still leaks,
contact OMNIFILTER Customer Service at 800.937.6664 M-F
7:30 AM-5 PM CST. Turn off icemaker if filtered water goes
to icemaker.
Leaks from fittings
1.
Relieve pressure by turning off water supply to the filter
and dispense water through the refrigerator door or T-flush
valve until water stops. For copper or plastic tubing, loosen
the compression nut and pull the tubing from the brass
fitting. Inspect to see if the ferrule and insert (plastic only)
are properly installed on the tubing. If so, reconnect tubing
finger-tight, then tighten nut snug about 1/2 to 1 turn with a
wrench. Open the water supply valve. If the leaks persist, or
if there are other leaks on the unit, turn off the water supply
1
and icemaker, then call OMNIFILTER Customer Service at
800.937.6664. If the fitting does not leak, turn on
the icemaker.
2

Publicité

loading

Ce manuel est également adapté pour:

Omnifilter r1100