Bosch GLL 3-15 X Professional Notice Originale page 7

Masquer les pouces Voir aussi pour GLL 3-15 X Professional:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
a)
(24) 5/8" tripod
a) Accessories shown or described are not included with the
product as standard. You can find the complete selection of
accessories in our accessories range.
Technical Data
Line laser
Article number
A)
Working range
– Laser lines
– Plumb point
B)C)D)
Laser line levelling accuracy
Typical self-levelling range
Typical levelling time
Operating temperature
Storage temperature
Max. altitude
Relative air humidity max.
Pollution degree according to
IEC 61010-1
Laser class
Laser type
C
6
Divergence
– Laser line
– Plumb point
F)
Tripod mount
Batteries
C)
Operating time approx.
– With 1 laser line
– With 2 laser lines
– With 3 laser lines
Weight according to
EPTA‑Procedure 01:2014
Dimensions (length × width × height)
– Without rotating platform
– With rotating platform
Bosch Power Tools
Line laser
Protection rating (excluding bat-
tery compartment)
A) The working range may be reduced by unfavourable environ-
B) ex-works
GLL 3-15 X
C) At 20–25 °C
3 601 K63 E..
D) The values stated presuppose normal to favourable environ-
15 m
E) Only non-conductive deposits occur, whereby occasional tem-
5 m
±0.2 mm/m
F) Only available in combination with the rotating platform
The serial number (4) on the type plate is used to clearly identify your
±3°
measuring tool.
< 4 s
Assembly
–10 °C to +45 °C
–20 °C to +70 °C
Inserting/changing the batteries
2000 m
It is recommended that you use alkaline manganese batter-
90 %
ies to operate the measuring tool.
E)
2
To open the battery compartment cover (3), press on the
locking mechanism (2) and remove the battery compart-
2
ment cover. Insert the batteries.
< 1 mW, 630−650 nm
When inserting the batteries, ensure that the polarity is cor-
rect according to the illustration on the inside of the battery
1
compartment.
If the status display (15) flashes, the batteries have to be re-
1.5 mrad
placed.
1.5 mrad
Always replace all the batteries at the same time. Only use
5/8"
batteries from the same manufacturer and which have the
same capacity.
4 × 1.5 V LR6 (AA)
Take the batteries out of the measuring tool when you
u
are not using it for a prolonged period of time. The bat-
24 h
teries can corrode and self-discharge during prolonged
14 h
storage in the measuring tool.
10 h
Working with the Rotating Platform
0.54 kg
(see figure A)
You can use the rotating platform (12) to rotate the measur-
ing tool 360° around a central, always visible plumb point.
122 × 83 × 129 mm
This enables you to set up the laser lines precisely, without
having to change the position of the measuring tool.
Dia. 151 × 203 mm
Place the measuring tool on the rotating platform (12) so
that the fastening grooves (13) of the rotating platform fit
between the corresponding fastening grooves (6) on the
bottom of the measuring tool. Turn the measuring tool clock-
wise to lock it on the rotating platform.
Unscrew the legs of the rotating platform (12) with the
height adjustment screws (10).
Roughly align the rotating platform using the spirit level (8).
If the measuring tool is mounted on the rotating
platform (12), you can use the fine adjustment screw (11)
to align vertical laser lines precisely with reference points.
mental conditions (e.g. direct sunlight).
mental conditions (e.g. no vibration, no fog, no smoke, no direct
sunlight). Extreme fluctuations in temperature can cause devi-
ations in accuracy.
porary conductivity caused by condensation is expected.
1 609 92A 4HL | (27.11.2020)
English | 7
GLL 3-15 X
IP 54 (dust and splash-
proof)

Publicité

Table des Matières
loading

Table des Matières