Hybernation Procedure; Maintenance Instructions - Astralpool 54068-MB Manuel Technique

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
Start filtering in order to circulate the swimming pool water inside the heat pump
exchanger. It is essential that the filtering equipment starts before the heat pump.
Switch the heat pump on. Turn on the magnetic circuit breaker. If purification is not
programmed, the heat pump will take readings to activate the purification pump if the
system thermostat determines that the water needs to be heated (Comfort).
Set the temperature you prefer (Description and operation of the controller).
The installing technician must adjust the valves of the by-pass according to the
pressures of the machine and must refrain from intervening anymore during the
warming-up period.
The heat pump should always operate together with the purification pump. We
must have the precaution to not interconnect timers or programmers which may
stop the filtration pump thus making the unit work without water flow.
The heat pump will take several days to reach the requested temperature: This is
completely normal.
7. 7. 7. 7. HYBERNATION

HYBERNATION PROCEDURE

PROCEDURE
HYBERNATION
HYBERNATION
PROCEDURE
PROCEDURE
Switch off the filtering pump.
Turn off the by-pass valves.
Open completely the drain cock of the condenser (bottom left)
Drain the exchanger to protect it from ice.
Once drained part of the condenser, close the drain cock.
Check the connectors and the (closed) by-pass valves of the heat pump to restrict the
entrance of foreign bodies or water to the exchanger.
8. 8. 8. 8. MAINTENANCE
MAINTENANCE
MAINTENANCE

MAINTENANCE INSTRUCTIONS

This operation must be obligatorily carried out by a professionally
qualified person. It should be carried out at least once a year and
includes several elements:
Cleaning of the rear evaporator with the aid of a thin brush and a non-dirty and non-
chlorinated water spray.
Revision of instructions and operating issues of the unit.
Revision of the safety mechanisms.
Dusting the circuit board.
Checking the earth connections.
Checking the gas pressure.
PREVENTIVE MAINTENANCE
PREVENTIVE MAINTENANCE
PREVENTIVE MAINTENANCE
PREVENTIVE MAINTENANCE
A record should be kept of each element repaired or substituted as well as of all maintenance
and repairs.
The surface of the exterior panels may be cleaned with a soft cloth and non-abrasive cleaner.
DISCONNECT THE EQUIPMENT FROM THE POWER SUPPLY before performing any maintenance
procedures.
EVAPORATOR COIL
EVAPORATOR COIL
EVAPORATOR COIL
EVAPORATOR COIL
The evaporator coil should be kept clean and free of obstacles which may hinder the circulation
of air through them. In order to clean it, use water (little pressure) and non-abrasive detergents
or cleaning liquids made specifically for it.