Temperature Regulation; External Stoppage - Astralpool 54068-MB Manuel Technique

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
0. Note that it is possible to control multiple heat pumps with one remote if all are configured
on the same channel. It is also possible to get additional remotes and control a heat pump with
various remotes.
To set the communication channel on the heat pump, see
chapter 5.7. (Page 17), technical menu. There is a screen
that sets the radio channel:
To set the communication channel on the wireless remote, press at the same time the keys
and
. After a few seconds, it will appear on the display the currently radio channel. To
change it, just press
or
to leave the configuration screen.
5.14.
5.14.

TEMPERATURE REGULATION

TEMPERATURE REGULATION
5.14.
5.14.
TEMPERATURE REGULATION
TEMPERATURE REGULATION
5.15.
5.15.
5.15.
5.15.

EXTERNAL STOPPAGE

EXTERNAL STOPPAGE
EXTERNAL STOPPAGE
EXTERNAL STOPPAGE
If the user must install any type of timing device or emergency stoppage device, it is important
to know that such a device can be installed by connecting it directly to the power board of the
system. The system is designed with external stoppage terminals which can be used for these
purposes. These terminals are shown in IMAGE 13 (page 191).
When these terminals are connected the machine will stop for
external reasons and the following message will appear:
GENERAL MODE
GENERAL MODE
GENERAL MODE
GENERAL MODE
When we want the unit to stop by means of external stoppage, we are to short circuit two
terminals, marked as EXT #1 in above figures. When these terminals are connected (short
circuited) the unit will stop by means of external stop. Once the terminals are disconnected, the
unit will start working again on the mode prior to external stop.
© ASTRALPOOL 2015 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT
. Once set the desired radio channel, just press
.
ENGLISH
ENGLISH
ENGLISH
ENGLISH
Radio Channel
00
button once
Heat Pump
External Stop
Pag: 24