Télécharger Imprimer la page

Setting The Maximum Temperature For The Dhw Storage Tank Via Heat Pump Only (T Hp Max); Setting The Cooling Operating Time (Cool Run Time); Setting The Heating Operating Time (Heat Run Time) - Olimpia splendid SHERPA MONOBLOC S1 E 6 Mode D'emploi Et D'entretien

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.
If the relative function is activated (paragraph 8.3), the value of these parameters will be stored in the
memory and automatically reset after any possible voltage failure.
5.
The default value is Tank heater: Logic 1.;
7.20.

Setting the maximum temperature for the DHW storage tank via heat pump only (T HP max)

After accessing the "T HP max" function, you can indi-
cate the maximum temperature for heating the water
in the water tank via the heat pump only. To set the
required value, use the "+" and "-" keys, entering a
value within the permitted range. After setting
the value, press "OK" to confirm and return to the high-
er level.
WARNING: this function must only be used by technical assistance personnel.
7.21.

Setting the cooling operating time (Cool run time)

This parameter is used to stabilise the temperature of the terminals once the operating set-point has been
reached. You are advised to set a higher value if the system terminals have considerable thermal inertia
(e.g. radiant floors).
WARNING: this function must only be used by technical assistance and/or installation personnel.
7.22.

Setting the heating operating time (Heat run time)

Refer to paragraph 7.20
T HP max
Range: 40~55°C
-
50°C
OK
Default: 50°C
+
Cancel
33

Publicité

loading