5.2.3.3. Connecting the HS nozzles to the cable

 Slide the cable through the nozzle(s) until they are connected to the cable at the correct
place. (Emitter point is already fitted and need not be tightened.)

5.2.4. Connecting the compressed air tube

Important:
 The compressed air to be used must be clean, dry and free of oil.
It is recommended to use an air filter.
The nozzles have a 1/8" BSP connecting nipple.
The shut-off cock of the compressed air tube is provided with a 10mm clamp coupling.
The user himself shall see to the required connecting materials.
Both plastic hose and metal tube are allowed for connection purposes, provided it is suited for
the relevant air pressure.

6. Putting into use

 Supply the nozzle(s) with compressed air.
 Switch on the power unit.

7. Functional check

The indicator lamp on the power unit is an indication of the available high voltage.
A Simco-Ion bar checker can be used to verify that the high voltage at the emitter point of the
nozzle(s) is on.
An electrostatic fieldmeter must be used to measure the efficiency of the nozzles. Measure the
charge on the material before and after the nozzle(s) have been used for cleaning by blowing
off. The charge measured should have disappeared after cleaning.