4. Technical specifications

Operating voltage
Current (from emitter point to earth)
Operating distance
Max. pressure
Pressure medium
Air connection of nozzle
Air connection of air tube
Air connection of air tube cock
Max. ambient temperature
Noise level at:
1 bar
2 bar
3 bar
measured at 60 cm distance, beside the
nozzle
Noise level at:
1 bar
2 bar
3 bar
measured at 60 cm distance, beside
multiple nozzles on an air tube
12
10
8
6
4
2
0
0
1
Fig.1 Air Consumption per nozzle.

5. Installation

Warning:
 Electrical installation shall be carried out by a skilled electrical fitter.
 When carrying out work on the equipment: de-energise the equipment.
H/HS/HE_UM_9752041010_NL_D_GB_F_V2_0
H nozzle
4 kV AC
max. 2.50mA
50 – 250 mm
6 bar
Air or nitrogen
1/8" NPT
3/8" BSP
10 mm
55° C
78 dB
86 dB
89 dB
88 dB
93 dB
96 dB
2
3
4
Airpressure (bar)
HS nozzle
7 kV AC
max. 20A
50 – 250 mm 50 – 250 mm
6 bar
55° C
76 dB
82 dB
84 dB
86 dB
90 dB
93 dB
HS-Nozzle
H -Nozzle
HE-Nozzle
5
6
HE nozzle
7 kV AC
max. 0.5 mA
7 bar
55° C
68 dB
76 dB
80 dB
80 dB
86 dB
91 dB