5.2.3. Loose nozzles connected to HV cable
5.2.3.1. Overview
If 2 or more nozzles are supplied for being connected to one HV cable, the "DE" (dead end)
nozzle is already connected to the cable. The other nozzles are supplied as loose items and can
be connected to the cable by client.
Fit the nozzles in the position you like, with the "DE" sprayer located farthest from the power unit
being removed. Then lay the HV cable via the nozzles to the power unit.
Connecting the HE nozzles to the HV cable
Warning:
Do not lay non-shielded high-voltage cables alongside sharp metal parts.
Do not kink the high voltage cables and do not lay them in sharp curves.
1. Remove the top.
2. Slide the internals to the top of the body.
3. Lay the cable in the curvature of the body.
4. Press the internals onto the cable so that the point sticks into the cable core.
5. Place the top over the body and internals so that it clicks onto the body.
Fig. 3 Configuration of HE nozzle
5.2.3.2. Connecting the H nozzles to the HV cable
1. Slide the HV cable through the H nozzle(s).
2. When the nozzle is connected to the cable at the correct place:
tighten the emitter point in the nozzle (3/16" spanner).