3 CONNECTIONS
3.1 Connections of the power supply with horn / Connections de l'alimentation
avec klaxon
Connector
POWER
(Tuchel 3pMT)
1
3
E
DATA IN
(Tuchel 7pFT)
DATA OUT
(Tuchel 7pFT)
DATA OUT for Shot Clock
(HARTING 5pMT)
4
1
3
2
Weight / Poids:
Power consumption / Consommation:
Horn / Klaxon:
Page 6
Pinning
1: L (115/230VAC)
3: N (115/230VAC)
E: GND
Power selection [see chapter 2.1] /
Sélection de la tension d'entrée [voir chapitre 2.1]
1: Connected to DATA OUT 1
2: +12V output (maximum 40mA)
3: Connected to DATA OUT 5
4: Connected to DATA OUT 6
5: Data input -
6: Data input +
E: GND
1: Connected to DATA IN 1
2: +12V output (maximum 40mA)
3: Data output -
4: Data output +
5: Connected to DATA IN 3
6: Connected to DATA IN 4
E: GND
1 : TRx- (RS485)
2 : TRx+ (RS485)
3 : GND
4 : +24VDC
E :
6.2Kg
max. 350VA
114dB
Version 1.1
3403.511