APPLICATION DOMAIN
2
The unstable key switch system is designed to control the following products SIMU:
- Range of SIMU motor: T5 / T6 / T8 / CENTRIS / SIMUBOX / SIMUBOX SI.
- Control boxes SIMU: SD250, SD410, SD510, RSA, RSA Pro.
Any use of the unstable key switch outside the scope described above is prohibited. It excludes, as any disrespect safety instructions and
instructions in this instruction sheet, any liability and warranty SIMU.
TECHNICAL CHARACTERISTICS
3
- Mechanical blocking of the cover which request to introduce and turn the key to have access to the wiring.
- Protection class IP 54
- Section of conductors 1,5 mm
- Cut off switch strength : 5A - 230V AC
- Hole marked on the box for gland of Ø16 (not supplied)
- 2 holes Ø5 for surface mounting application
- Supplied with 3 identical keys (European cylinder)
- Unstable mode
- Surface mounting
- Dimension: 73.5 x 73,5 x 45
- Class I
- Power supply: 12/24V DC and 12/24V AC / 120V/60Hz AC ; 230V/50Hz AC and 220V/60Hz AC
ASSEMBLY / DISMANTLING
4
Dismantling:
1- Unscrew the screw ①.
2- Remove the cover ② and the seal.
3- Insert and turn the key ③ in the counterclockwise (45°) way, then remove the mechanism.
4- Remove the electrical switch.
Installation of the key box :
1- Fix the box on the wall thanks to the 2 Ø5 holes. Take care of the assembly way.
2- Set the box and screw on the screws. Take care of the assembly way.
3- Connect the switch according to the connection diagram of the paragraph 3.
4- Replace the switch int he box.
5- Set the mechanism with the key at 45° counterclockwise relative to the vertical
6- Set the seal and the cover ②
7- Screw the screw ①
WIRING
5
The installer must ensure that the implementation respect electrical installation modality existing in country of implementation.
DIRECT CONTROL OF A MOTOR
- To change the motor rotation direction,
reverse wires ② and ③ of the motor.
CONNECTION BOX (not included)
Connecteur rapide
sans vis
BLUE
BROWN
BLACK
RED (power supply phase)
GREEN / YELLOW
UTILIZATION - MAINTENANCE
6
- Insert the key in the lock cylinder
- Turn the key:
- Clockwise to open the curtain ①
- Counterclockwise to close the curtain ②
- Keep the key turn until the desired position.
- Remove the key
- The product is maintenance-free.
2/2
minimum.
2
KEY SWITCH
L
N
PE
①
③
②
①
CONTROL OF AN AUTOMATIC CONTROL BOX
- See control box instruction manual
CONTROL BOX
SD250 - SD410 - SD510
RSA - RSA PRO
=
KEY SWITCH
NOT USED
②
=