English – 12
The control unit shows whether critical errors or less
critical errors occur in the eBike system.
The error messages generated by the eBike system
can be read via the eBike Flow app or by your bicycle
retailer.
Less critical errors are shown by the assistance level
LED (5) flashing orange. Pressing the select but-
ton (2) confirms the error and the assistance level
LED (5) once again continuously shows the color of
the set assistance level.
Critical errors are shown by the assistance level
LED (5) and the battery charge indicator (3) flashing
red. In the event of a critical error, visit a bicycle re-
tailer as soon as possible. Do not connect a charger
to the system.
0 275 U07 3RL | (09.07.2021)
Troubleshooting
Via a link in the eBike Flow app, information about
the error and support for rectifying the error can be
displayed.
Less critical errors
You can use the following table to rectify the errors
yourself if necessary. Otherwise, please contact your
bicycle retailer.
Number
0x523005 The indicated error numbers show that
0x514001
0x514002
0x514003
0x514006
Critical errors
Troubleshooting
there is interference when the sensors
detect the magnetic field. See whether
you have lost the magnets while riding.
If you are using a magnet sensor, check
that the sensor and magnet have been
properly installed. Make sure too that
the cable to the sensor is not damaged.
If you are using a rim magnet, make
sure that you do not have any magnetic
field interference in the vicinity of the
drive unit.
Bosch eBike Systems