Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Verify that the VersiCharge is in the 'Power Available' state by
ensuring that only the 'Power' indicator is illuminated.
• Press and hold both the 'Pause' button and the 'Delay Timer' button for
5 seconds. The halo will blink green three times, and fade out to off.
• To re-activate, press and hold both the 'Pause' button and the
'Delay Timer' button for 5 seconds. The halo will fade in from off
and then blink green three times.

4.7 Alternate input

An Alternate input can be used to control the VersiCharge. Examples
include demand response switches, building automation systems, digital
sensors, etc.
• Wire a digital input into the dry contact located in the connection area
inside the VersiCharge. See installation Section 3.6 for installation
details.
• When this external contact is closed, the alternate input will control the
VersiCharge, preventing it from entering the 'Charging' state.
• There is no override capability at the VersiCharge, so if a user would
ever want to use the VersiCharge during an auxiliary control event,
other override methods are required.