Hard-Wired Installation; Bottom-Fed, Hard-Wired Installation - Siemens VersiCharge Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Plug the VersiCharge into the receptacle
• Mount the VersiCharge to the Mounting Bracket
• Secure to the Mounting Bracket, securing with two drywall
screws (2 ½ inches or longer). Additional anchors may be
required for masonry or concrete walls.

3.4 Hard-wired Installation

• Bottom-fed, Hard-wired Installation

• Mounting
• Locate a stud within the wall to attach the mounting bracket. For
concrete or masonry walls, install appropriate anchors.
• Verify that the stud or anchor and surrounding materials can
• Verify local code with respect to installation height:
• Installation height is regulated by the NEC®, however this
• Using 7/16 inch socket head and drill, attach the Mounting
Bracket to the wall using the two provided lag screws.
• Mount the VersiCharge to the Mounting Bracket.
© 2012 Siemens Industry, Inc.
handle the 20+ lbs load of the VersiCharge.
can vary based on local jurisdiction.
• NEC® 2011 specifies:
• Indoor (NEC® Article 625.29B) = installation 18 - 48
inches above ground level.
• Outdoor (NEC® Article 625.30B) = installation 24 – 48
inches above ground level.
- 17 -
Document Number: 813540

Publicité

Table des Matières
loading

Table des Matières