Water Drainage Hose; Connection Of Power Supply; Grounding Instructions - Haier HWD1000 Guide De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

Water drainage hose

• The height of the terminal for the water drainage hose should be between
31"-40". The water drainage hose must be securely placed to the clip of the
washing machine.
• Use the water drainage support supplied as an accessory for proper
installation of the water drainage hose. Fix the water drainage hose support
with waterproof string. The water drainage hose should not be extended more
then 98" (longer extension will result in concurrent water inflow and outflow).
The diameter of the extension hose should be the same as the original hose.
Caution: Water drainage hose must not be immersed in water. The original and
extension hoses should be tightly connected.

Connection of power supply

Check the following items before connecting to the power supply.
• The socket conforms to the maximum power load (The maximum current load
of the socket and power supply cable should not be less then 15A).
• Power supply voltage conforms to the required value (120V/60Hz).
• The power supply socket and the plug of the washing machine are compatible.
If they are not compatible, refer to a washing machine technician or a
designated service point for power cable replacement.
• USE SUPPLY CONDUCTORS RATED 105 ºC (221 ºF).

Grounding instructions

• This appliance must be grounded. In the event of malfunction or breakdown,
grounding will reduce the risk of electric shock by providing a path of least
resistance for electric current. This appliance is equipped with a cord having an
equipped-ground conductor and a ground plug. The plug must be plugged
into an appropriate outlet that is properly installed with accordance to local
codes and regulations.
WARNING: Improper connection of the equipped-ground conductor can result
in a risk of electric shock. Check with a qualified electrician or
serviceman if you are in doubt as to whether the appliance is
properly grounded. Do not modify the plug provided with the
appliance.
WARNING: Certain internal parts are intentionally not grounded and may
present a risk of electric shock only during servicing. Service
Personnel–Do not contact the following parts while the appliance is
energized: electromagnetic valve, computer board, door lock, drain
pump, drying motor, capacity bracket assembly, etc...