Heating Unit Mod. 303 / Mod. 300 must be fix installed and permanently wired.
Use distribution box of min IP 54.
Local national rules and regulations must be adhered to!
230 V / 400 V AC; 50 Hz; 1~; max. 3,0 kW; According connection diagram, observe VDE 0100!
All installation, maintenance and inspection works of the unit must be carried out only by an
authorised and qualified specialist.
Heating Unit must be used in conjunction with a own residual
current device 230 V - 0,03 A / 400 V - 0,03 A !
A damaged heating or pump can cause that the residual current circuit breaker triggers and the
heating unit and pump is out of function. This leads to the possibility that the water supply line
risks to freeze due to certain cold outside temperature.
Special and corresponding steps have to be taken at the spot by the user to protect it
against freezing: e.g. frost protection heating cables, warning system, etc.

Technical data:

Voltage supply
Voltage supply
Output
Pump supply
STB
Dust/water protection
Thermostat
Determination of Quantity of Drinking Bowls
Flow rate of water
circuit
½"
¾"
*
150 l/min 90 l/min
Tested with 4-5 bar
* Theoretic peak values depend in practice on local circumstances and can result in lower values.
Example:
Local circumstances:
Question:
Calculation:
Answer:
Water flow quantity depends on the following conditions:
Water pressure, length of pipes and cross sectional area as well as the quantity of reduction
pieces and curves.
Experimental values, based on field test, revealed that not all the drinking bowls are actuated at
the same time.
This way the result /field test has to be multiplied with factor two.
Electric Connection
1x230 V +/-10% 50 Hz
1x400 V +/-10% 50 Hz
PWM 0-3000 W
230 V AC 2 A
90° C opener/h
eating
IP 44
0-40° C
Mod. 671 Mod. 690
water flow
water flow
21 l/min
100 l/min
*
16 l/min
90 l/min
12 l/min
56 l/min
6 l/min
20 l/min
4 bar of pressure, ¾" water line (150 l/min)
How many cattle bowls can be connected in addition?
150 l/min : 12 l/min = 12 pieces
12 pieces x 2 ( empirieal values) = 24 pieces
24 pieces of cattle drinking bowls can be connected.
Mod. 303
Connections
Mod. 300
Connections
Water pressure range
Water connection entry ¾"
Water connection exit
Size
Weight
Mod. 700 Cattle/Horses
drinking
bowls
water flow
water flow
12 l/min
44 l/min
11 l/min
36 l/min
8 l/min
25 l/min
4 l/min
9,6 l/min
3 x 1,5 mm²
5 x 1,5 mm²
1 - 4 bar
¾"
l w h
60x40x22 cm
22 kg
Pig
drinking
bowls
water flow
1,3 l/min
1,1 l/min
0,9 l/min
0,7 l/min
Pressure
4 bar
3 bar
2 bar
1 bar