5.
Processing
Damage to, or destruction of the
product
cleaning/disinfecting or steriliza-
tion!
CAUTION
Only clean and disinfect the
product manually.
Do not sterilize the product
under any circumstances.
5.1 Cleaning/Disinfecting
Note
Always follow disposal and hygiene instructions and
regulations!
Manual cleaning/disinfecting
Risk of electric shock and fire
hazard!
Unplug the unit before cleaning.
DANGER
Make certain that no fluids will
penetrate the product.
Leave the product exposed to
air for at least 1 minute after
cleaning/disinfecting.
Damage to the product due to
incorrect cleaning or inappropriate
cleaning/disinfecting agents!
CAUTION
Use any commercial detergent
for surface cleaning.
Never immerse the product in
water or detergent.
Do not introduce any fluid into
the charging bays.
Clean the contacts in the charg-
ing bays, applying extreme care.
caused
by
mechanical
Wipe the shell of the product with a lint-free cloth
moistened with a commercial disinfectant for wipe
disinfection.
If necessary, after the appropriate exposure time,
wipe off any residue of the cleaning/disinfecting
agent with a lint-free cloth moistened with clean
water.
Dry the product with a clean, lint-free cloth.
If necessary, repeat the cleaning/disinfecting
process.
Cleaning the air filter
Note
The air filter must be cleaned once a week or whenever
necessary!
Slide back and remove air filter 7.
Blow through or wash air filter 7.
Slide dry air filter 7 into its seating.
5.2 Control, care and inspection
Allow the product to cool down to room
temperature.
Inspect the product after each cleaning and
disinfecting cycle to be sure it is clean, functional
and undamaged.
Lubricate the shearing head as appropriate, see
Chapter Lubricating the shearing head.
Check the product for any damage, a typical
running noise, overheating or excessive vibration.
Inspect the cutting set for broken, damaged or
blunt cutting edges.
Set aside the product if it is damaged.
7