Checklist:
L.p Scope
1
General control
Control of gas
2
control system
Combustion chamber
3
control
4
Control device control
5
Decorative elements
Actions
Perform firing up procedure of your gas garden fireplace.
Check the operation of all security systems.
Check if the main burner flame burns steadily.
Check that the main burner burns evenly.
Check the gas connections for leaks.
Check that the cylinder chamber ventilation is not blocked.
Check that the gas control system components are not exposed to
high temperatures.
Check that the inner chamber and the elements installed in it are
not exposed to moisture. Check that the connecting cables show
no signs of corrosion.
Check that the pilot burner is not obstructed by decorative
elements.
Check if the thermocouple is within the pilot burner flame.
Check whether the combustion chamber requires cleaning.
Check the glasses if there are any visible dirt of sooting process.
Check that all air inlets to the combustion chamber are clear. If
necessary, clear the holes.
Check the combustion chamber for signs of corrosion. If necessary,
remove corrosion and cover the defects with a new layer of
fireplace paint.
Check if the main burner ignites smoothly.
Check for a puncture in the circuits.
Check that the components of the control system are not exposed
to overheating.
Check if the decorative elements require cleaning.
Check that the decorative elements are not in contact with the
glass.
Check if the decorative elements cover the openings venting the
hearth.
Check that the decorative elements have not been damaged.
EN