Swivel Conduit Mounting
CSMA
M1
M2
Tamper
Spring
M3
Holes
M4
Note:
The CSMA is required when wiring is in a pipe external to the wall. It should be ordered separately P/N
RA300S.
a. Choose the direction upon which to mount the CSMA according to the required diameter:
16mm (0.63 inches) or 21mm (0.83 inches).
b. Insert conduit to the CSMA.
c. Secure CSMA to the wall through points (M1, M4).
d. Insert external cables and tamper wires from the conduit through the swivel wires passage
of the swivel (Figure 8, Detail A).
e. Secure swivel to the wall through holes S1, S3, S6 and S8.
Note:
The Tamper spring S5 (Figure 8) should make contact with the wall through the tamper spring holes M2 or
M3 on the CSMA. Make sure to hear the tamper "Click" when connecting to the wall.
7. Insert tamper wires and external cable wiring from Standard Swivel through knockout W1 on
the external base (Figure 8, Detail B).
8. Connect the external base to the swivel using the dedicated snaps (Figure 9).
PCB
(using Conduit Metal Swivel Adaptor - CSMA, Figure 8, Detail A)
Detail A
Standard Swivel
S1 S2
Ø
mm
16
S9
S8
Ø
21 mm
Swivel Wires
S7 S6
Passage
Swivel to External Base
Connecting Screws
Internal Base
Angle Locking
Screw
(See Note 2)
WatchOUT PIR Installation Manual
S3
S1
S4
S5
Tamper
(see Detail C)
Figure 8
Snaps
External Base
W1
S1
S2
S3
Swivel Assy
Connecting Screw
(See Note)
Figure 9
Detail B
Snaps
W1
S2
S3
Detail C
See Detail A
Detail A
11

Publicité

Table des Matières
loading

Table des Matières