WatchOUT ID: DIP Switches 1 - 5
ID
1
2
3
01
OFF OFF OFF OFF OFF
02
ON
OFF OFF OFF OFF
03
OFF ON
OFF OFF OFF
04
ON
ON
OFF OFF OFF
05
OFF OFF ON
06
ON
OFF ON
07
OFF ON
ON
08
ON
ON
ON
09
OFF OFF OFF ON
10
ON
OFF OFF ON
11
OFF ON
OFF ON
12
ON
ON
OFF ON
13
OFF OFF ON
14
ON
OFF ON
15
OFF ON
ON
16
ON
ON
ON

ProSYS Programming

The following section describes the additional software programming options, added to the
ProSYS software, that concern the settings of the Without PIR as a BUS detector. Up to 32 BUS
detectors can be added to the system (16 in ProSYS 16) and each of them comes at the expense
of a zone in the system.
It is recommend reading and fully understanding the ProSYS Installation and User Manuals,
before programming the WatchOUT.
Notes:
The WatchOUT is compatible with the ProSYS software Version 4.xx and above.
The WatchOUT can be programmed via the U/D Software from UD Version 1.8 and above.
For maximum operation stability, it is best NOT to exceed a total of 300 meters (1000 feet) of wiring when
connecting the WatchOUT to the BUS
The WatchOUT is part of a new accessory category, BUS zones. Therefore, Adding/Deleting the
WatchOUT is identical to any other accessory with the following exception:
Each BUS Zone Detector should be assigned to a Regular Zone.
Any BUS detector can be assigned to a physical wired zone or to a virtual zone.
Physical zone: Any zone on the ProSYS PCB (zones 1-8) or on a wired zone expander
(ZE08, ZE16).
Virtual zone: Any zone on a BUS zone expander defined as BZ08 or BZ16.
Notes:
Virtual BUS zones are cost effective. They enable to expand your system zones without adding physical zone
expanders.
The virtual BUS zone expander can be used only for BUS zone detectors.
To add a BUS zone expander select type BZ08 or BZ16 when adding a zone expander (Quick key [7][1][2])
To Add / Delete the WatchOUT 312PIR
1. From the installer menu enter the Add/Delete menu: Quick Key [7][1][9][5] for BUS Zones
detectors
2. Use the
ID number for which you want to assign (or delete) a detector.
Note:
Make sure that the detector's physical ID number is identical to the ID number you select
during programming
3. Place the cursor on the TYPE field and use the
WatchOUT 312PIR detector.
4
5
OFF OFF
OFF OFF
OFF OFF
OFF OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
/
or
/
WatchOUT PIR Installation Manual
ID
1
2
3
17
OFF OFF OFF OFF ON
18
ON
OFF OFF OFF ON
19
OFF ON
OFF OFF ON
20
ON
ON
OFF OFF ON
21
OFF OFF ON
22
ON
OFF ON
23
OFF ON
ON
24
ON
ON
ON
25
OFF OFF OFF ON
26
ON
OFF OFF ON
27
OFF ON
OFF ON
28
ON
ON
OFF ON
29
OFF OFF ON
30
ON
OFF ON
31
OFF ON
ON
32
ON
ON
ON
keys to position the cursor over the Bus Zone
/
4
5
OFF ON
OFF ON
OFF ON
OFF ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
key to select OPR12 for the
15