Relay Mode / BUS Mode Jumper
J-BUS jumper (located on the PCB between the red and green
LEDs) is used to define the detector's mode of operation as
follows:
Standard Swivel Installation
The Outdoor detector packaging contains a standard swivel for flexible installation. Please follow
the instructions below for mounting the detector with the Standard Swivel:
1. Open WatchOUT front cover (Unlock C1, Figure1).
2. Release internal base (Unlock I1, Figure 2).
3. Open knockouts on external base (Figure 6, Detail B)
•
W1: Wires knockout
•
S1,S2: Knockouts for securing external base to Standard Swivel
•
S3: External base locking screw knockout
4. On the swivel accessory remove the required swivel cable wiring knockout S2, S7 or S9
(Figure 6, Detail A).
5. Remove back tamper from the internal base (see "Changing Back Tamper Position"
paragraph) and connect it to S5 (Figure 6, Detail A) on the Standard Swivel.
Note:
Ensure that you see the engraved UP mark on the upper front face of the swivel.
6. Select the mounting installation type as follows:
Wall Mounting
a. Insert external cable wiring through knockouts S2, S7 or S9 and extract them (including the
tamper wires) through the Swivel Wires Passage (Figure 6, Detail B).
b. Secure swivel to the wall through holes S1, S3, S6 and S8.
Swivel Conduit Mounting
CSMA
M1
M2
Tamper
Spring
M3
Holes
M4
Note:
The CSMA is required when wall external wiring is used and protection pipe is required. The CSMA should
be ordered separately - P/N RA300SC0000A.
a.
Choose the direction upon which to mount the CSMA according to the required diameter:
16mm (0.63 inches) or 21mm (0.83 inches).
b.
Insert conduit to the CSMA.
8
(using Conduit Metal Swivel Adaptor – CSMA, Figure 6, Detail A)
Detail A
Standard Swivel
S1 S2
Ø
mm
16
S9
S8
Ø
21 mm
Swivel Wires
Passage
WatchOUT 315DT Installation Manual
S3
S1
S4
S5
S7 S6
Tamper
(see Detail C)
Figure 6
Relay
BUS Mode
Mode
Detail B
Snaps
W1
S2
S3
Detail C