Télécharger Imprimer la page

HIKOKI VB 3616DA Mode D'emploi page 19

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
WARNING SIGNALS
This product features functions that are designed to protect the tool itself as well as the battery. During work, from the time
the switch is being pulled and three seconds after its release, each of the protective functions may be activated, resulting in
the Mode indicator lamp to blink as shown in Table 3 to notify the user. When any of the safeguard functions are triggered,
immediately remove your fi nger from the switch and follow the instructions described under corrective action. (Fig. 32)
Safeguard Function
Overload Protection
Temperature Protection
HOW TO RECHARGE USB DEVICE
(UC18YSL3)
(1) Select a charging method
○ Charging a USB device from a electrical outlet
(Fig. 33-a)
○ Charging a USB device and battery from a electrical
outlet (Fig. 33-b)
(2) How to recharge USB device (Fig. 34)
(3) When charging of USB device is completed (Fig. 35)
MAINTENANCE AND INSPECTION
CAUTION
Be sure to turned off the switch and remove the battery
before maintenance and inspection.
1. Inspecting the cutter
Continued use of a dull or damaged cutter will result in
reduced cutting effi ciency and may cause overloading of
the motor. Replace the blade with a new one as soon as
excessive abrasion is noted.
2. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure that
they are properly tightened. Should any of the screws be
loose, retighten them immediately. Failure to do so could
result in serious hazard.
3. Maintenance of the motor
The motor unit winding is the very "heart" of the power
tool. Exercise due care to ensure the winding does not
become damaged and/or wet with oil or water.
4. Inspection of terminals (tool and battery)
Check to make sure that swarf and dust have not
collected on the terminals.
On occasion check prior, during and after operation.
CAUTION
Remove any swarf or dust which may have collected on
the terminals.
Failure to do so may result in malfunction.
5. Cleaning on the outside
When the power tool is stained, wipe with a soft dry cloth
or a cloth moistened with soapy water. Do not use chloric
solvents, gasoline or paint thinner, for they melt plastics.
6. Storage
Store the power tool in a place in which the temperature
is less than 40°C and out of reach of children.
NOTE
Storing lithium-ion batteries.
Make sure the lithium-ion batteries have been fully
charged before storing them.
Prolonged storage (3 months or more) of batteries with
a low charge may result in performance deterioration,
signifi cantly reducing battery usage time or rendering
the batteries incapable of holding a charge.
LED Light Display
On 0.1 second/off 0.1 second
On 0.5 second/off 0.5 second
Table 3
Remove the cause of the overloading.
Allow the tool and battery to thoroughly cool.
However, signifi cantly reduced battery usage time may
be recovered by repeatedly charging and using the
batteries two to fi ve times.
If the battery usage time is extremely short despite
repeated charging and use, consider the batteries dead
and purchase new batteries.
CAUTION
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
Important notice on the batteries for the HiKOKI
cordless power tools
Please always use one of our designated genuine
batteries. We cannot guarantee the safety and
performance of our cordless power tool when used with
batteries other than these designated by us, or when
the battery is disassembled and modifi ed (such as
disassembly and replacement of cells or other internal
parts).
GUARANTEE
We guarantee HiKOKI Power Tools in accordance with
statutory/country specifi c regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a HiKOKI Authorized Service Center.
Information concerning airborne noise and vibration
The measured values were determined according to
EN62841 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 94.0 dB (A)
Measured A-weighted sound pressure level: 88.5 dB (A)
Uncertainty K: 3 dB (A).
Wear hearing protection.
Vibration total values (triax vector sum) determined
according to EN62841.
Vibration emission value
Uncertainty K = 1.5 m/s
19
English
Corrective Action
a
h, B = 0.6 m/s
2
2

Publicité

loading