V - What to do if...? ... Check.
What to do if...?
No broadcasting since the
control box on the sounders.
No DHCP server on the
network
No LEDs lit on the control box
Nothing is released when
pressing
26
1) The multicast address is identical between the master clock
and control box.
2) Network parameters are supported: control box must be on
the same Ethernet network as the computer with the Sigma
software.
1) By default the control box takes on the following IP setting
(after 3min):
- IP: 192.192.223.100 (1st control box), 192.192.222.101 (2nd
control box), etc.
- MASK: 255.255.0.0
- Gateway: 0.0.0.0
- DNS: 0.0.0.0
(After 15 minutes, the control box asks an address DHCP
server).
2) Using the Sigma software (Configuration> IP devices>
Network button) to set the network settings control box (product
identification with the MAC address on the tag on the back of
the product).
1) the maximal power of the switch PoE is sufficient to feed all
the products connected to the switch.
2) the length of the cable is lower than 100 meters (refer to the
standards of network cabling).
3) The power output of the switch is sufficient (IEEE 802.3af) to
power the product.
4) Control box is the broadcast area of the master clock Sigma.
5) The external input is activated from the Sigma software.
1) The multicast address is identical between the master clock
and control box.
2) The allocation of buttons is correctly associated with a zone
or group.
3) The method of housing control box (SIGMA or Independent)
... Check that