4.4 Alarm configuration

This page is used to enable device supervision, to define the information to be transmitted
and the destination server. One or more settings can be defined and configured as alarms.
The following information is displayed:
- Tick the SNMP box: activates the SNMP network service for device supervision
from a control PC.
- Version: choice of SNMP protocol version
- Community: fleet or area of Harmonys Flash units defined by the user. It is crucial to
give all Harmonys Flash units on the network the name 'Community'.
- Tick SNMP Trap box: activates (or not) the automatic sending of error messages to
SNMP managers.
- SNMP Manager 1/2/3: IP addresses of servers receiving alerts from the clocks. SNMP
Manager redundancy increases the reliability of alerts.