Recalibration
1. During calibration, pay attention to the alignment of the Titanium and the
displays for the X and Y axes (H). Always calibrate both axes. You can
switch between axes with button (19) of the additional remote control.
Alternatively the X- and Y-Axis can be changed with the button
(SensoCommander).
In vertical mode the Z-Axis is automatically switched on.
2. Set the device to calibration mode:
Switch off the Titanium, and then, with the auto/man button (F) de-
pressed, switch on again, briefly press ON/OFF button (G). Keep the
auto/man button (F) depressed until the tilt display (K) lights up. When
this happens, the auto/man button (F) can be released.
3. Correcting calibration:
Using the buttons (20) of the Commander 50 or the buttons (15) of the
SensoCommander, move the laser from its present position to the height
of reference point A2.
4. Ending calibration:
Cancel: By switching off the Titanium, the entire calibration is rejected
and the previous status restored.
Save:
The new calibration can be saved by pressing button (21) of the
additional remote control or SensoCommander.
Alternatively the new calibration can be saved with the button
(SensoCommander).
Note:
Regularly check the calibration before
use, after transport and after extended
periods of storage. Always make sure
to control all axes.