INSTALLATION
Due to the complexity in installing the hood, we suggest to do it minimum in two people
When installing the hood in recycling version it has to be taken into consideration that space re-
maining between the hood and the upper limit (ceiling or self) is at least 8-10 cm.
On the wall, draw:
• a Vertical line up to the ceiling or upper limit, at the centre of the area in which the hood is
to be fitted;
• a Horizontal line at a minimum of 826 mm above the Cooker Top; .
• As indicated, mark a reference point at 100 mm to the right of the vertical reference line.
• Repeat this operation on the other side, checking that the two marks are level.
• As indicated, mark a reference point at 390 mm above the horizontal reference line, and at
100 mm to the right of the vertical reference line.
• Repeat this operation on the other side, checking that the two marks are level.
• Drill at the points marked, using a ø 10 mm drill bit.
• Insert the plugs 11 into the holes.
EN
Wall drilling and bracket fixing
100
11
12a
100 100
FTU 3807-P WXS 70H
100
170
2
22