1) Installation on the counter
The image below shows the recommended method to drill the hole on the counter.
CENTER
OF MACHINE
HERE THE POSITION OF THE
POWER CORD
140 mm
5,5 in.
290 mm
11,5 in.
HERE THE POSITION
OF THE DRAIN TUBE
630 mm - 24,8 in. (4 groups)
195 mm - 7,7 in. (1, 2 and 3 groups)
Fig. 5 - Hole on the Counter
FROM ∅100 TO ∅120 mm
FROM ∅4 in. TO ∅4,7 in.
HERE THE POSITION WHERE WE
170 mm
SUGGEST TO MAKE THE HOLE
6,7 in.
ON THE TABLE
WATER INLET HOSES
60 mm
2,4 in.
65 mm
2,5 in.
150 mm
6 in.
2) Water test kit
In order to enable you to check if your water
supply is within the suggested ranges, La
Marzocco machines will be equipped with
two units of a quick water test kit (see image
below) including 6 test-strips and instruction
cards.
The
parameters
that
you
can
measure
are
Total
Hardness,
Total Iron, Free
Chlorine,
Total
Chlorine, pH &
Total
Alkalinity,
Chlorides.
Ideally,
you
should
perform
a test on the
water BEFORE the water treatment system
and again AFTER the water system in order
to verify if this is actually matching our
suggested ranges.
Once the test has been performed, learn
which treatment system is most appropriate
for your particular water supply by filling out
the online water calculator on our website:
LA MARZOCCO WATER CALCULATOR (http://
www.lamarzocco.com/water_calculator/).