If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
In general, lighting effects should not be connected to dimming-packs.
Before taking into operation for the first time, the installation has to be approved by an expert!

OPERATION

After you connected the effect to the mains, the HPS-1500 start running. The ventilation fans begin to rotate
and the display lights up.

DMX-512 connection / connection between fixtures

RGB
DMX
C&B
SIGNAL
COLOR
MODE
UP
DOWN
The wires must not come into contact with each other, otherwise
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the fixture or one fixture with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
DANGER TO LIFE!
RGB
DMX
C&B
SIGNAL
COLOR
MODE
UP
DOWN
120 Ohms
the fixtures will not work at all, or will not work properly.
DMX
SIGNAL
MODE
UP
DOWN
21/46
RGB
C&B
COLOR
DMX-512 Controller