C16i...
7
Scope of supply
D Pendulum load cell with connection cable, flexible tube and tube clip
D Dowel pin for rotation stop device (Load introduction parts have to be or-
dered separately)
D Plastic bag with grease
D Mounting instructions
7.1 Mounting accessories (optional)
Thrust pieces
Mounting variation 1:
S C16/ZOU44A Thrust pieces (stainless steel) for above and below
Mounting variation 2:
S EPO3/50t
S C16/EPU44A Thrust piece for below, incl. 3 excentric washers
8
Mounting
General hints
D Please handle the load cell carefully.
D Use appropriate lifting gear when mounting the weighing device.
D Do not overload the load cell, not even for a short time (e.g. due to
unevenly distributed supporting loads).
D If required, use supporting elements (dummies) of the same height for
alignment purposes.
The C16i... is a pendulum load cell designed to automatically restore the
mounting construction to a stable initial position in the case of a lateral dis-
placement of the load introduction (= skewing of the load cell). The maximum
permissible lateral displacement or skewing (see Dimensions = Chapter 12)
must not be exceeded, otherwise the load cells or load introduction parts
might be damaged. The easiest and most common solution for this problem
are the appropriate stops on the mounting construction (weighing platform)
which must be carefully adjusted within the specified values.
A1461--1.2 de/en/fr
(1 Set = 2 pcs.), for use with C16.../≤60 t up to a
max. load per load cell of 40 t, incl. 3 excentric washers
Thrust piece for above, incl. spanner
23
HBM