Dustcontrol DC 5800c 5 kW Notice Originale page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Trouble Shooting
Problem
Motor will not start.
The motor stops directly
after starting.
Pump runs but no suction.
Pump runs but poor suction.
Machine blows dust.
Abnormal sound from
machine.
2010-09-06
Fault
Machine not connected.
Thermal overload tripped.
Incorrect fuse.
Thermal overload not set
correctly.
Hose not connected.
Hose plugged.
No plastic sack/container
on the cyclone.
Pump rotation backwards.
Hole in the hose.
Plugged fi lter.
Hose too long or too small.
Hose is kinked.
Machine top is mounted
incorrectly.
Dust is packed in the
cyclone.
Filter is perforated or has
come loose.
Particles in the pump.
DC 5800c 5/7.5 kW - 11
Solution
Make sure connection.
Wait 5 minutes.
Change to correct circuit.
Electrician should adjust.
Connect the hose.
Find and remove block.
Mount the correct sack/
container.
Electrician should change
phases.
Change or repair hose.
Clean or change fi lter.
Change the hose.
Check and free.
Adjust the mounting.
Take off the top and clean
out.
Check the fi lters and change
if necessary.
Order service.
Part No 9090