SELF LEVELLING PROCEDURE / DISPLAY ILLUMINATION
If the TILT function is activated and the level is disturbed (rotation stopps) the self-levelling procedure can
be started from this position if required. Press the button short.
Please check if the instrument has been disturbed.
Press the button long (2 sec.) to switch on / off display the illumination.
SLOPE SETTING
Press the button
is below the sign. Change the sign with the buttons
digit. Set the slope values with the buttons . Press the button
button
again long to select the slope setting of the Y axis. The slope setting of the Y axis is the same
as above. After 8 sec without entry the instrument will automatically store the values set. For confirmati-
on the instrument will beep. Then, the TILT mode preparation will start (3 status).
USE OF THE TELESCOPIC VIEWFINDER
Aim the X axis of the laser exactly in the direction of the axis which has to be tilted with the help of the
notch and bead on the top cover. At larger distances please use the telescopic viewer which can be
mounted on top of the instruments housing.
Look into the viewer from this side with a distance of about 10 – 15 cm!
Please note: The telescopic viewer is only used to align the slope axis to the target.
Single axis
X = -10,000 % up to +10,000 % or Y = -1,000 % up to +25,000 %
Dual axis
X and Y ≤ 20,000 %
Examples of maximum grade values
Single axis
X = - or +10,000 % or Y = -1,000 or +25,000 %
Dual axis
X = ±5,000 % and Y = +15,000%
=> Sum of grade values = < 20,000 %
26
for 2 sec to enter into the slope mode. The X symbol and „+" will flash. The curser
. Press the button
short to go to the next
again to select the next digits. Press the