Service tasks
9.5
Changing the vacuum pump oil
!
WARNING! Danger of fatal electric shock
Touching uninsulated parts may result in serious injury.
Switch off the AirCon Service Center and unplug it from the power
supply before opening the housing.
The AirCon Service Center may only be repaired by personnel
authorized by Dometic.
1. Before changing the oil, let the vacuum pump run for about
10 minutes (manually, via the menu).
!
CAUTION!
The following steps may only be performed by qualified personnel.
2. Take off the front panel:
Undo the screws (D) on the control panel and lift it up. Then undo the
screws (E) on the bottom of the front panel and take it off.
102
D
E
ASC 1100G
D
E
EN