Service tasks
9.6
Changing the vacuum pump oil
!
WARNING!
Switch off the AirConServiceCenter and unplug it from the power
supply before opening the housing.
1. Before changing the oil, let the vacuum pump run for about 10 min-
utes (manually, via the menu).
The following steps may only be performed by qualified personnel.
2. Take off the front panel:
Undo the screws (D) on the control panel and lift it up. Then undo the
screws (E) on the bottom of the front panel and take it off.
108
D
E
ASC5300G
D
E
EN