ABOUT ERROR LAMP OF AC/DC ADAPTER
Status
Before use
Power on
Adapter
Power
suspended
Power
Box
suspended
26
00Book̲C3607DWA̲NA.indb 26
00Book̲C3607DWA̲NA.indb 26
Table 6
Indications of the indicator lamp
Power
Lamp
(GREEN)
Blinks
Lights
Blinks
Lights for 0.5 seconds. Does not light
for 0.5 seconds. (off for 0.5 seconds)
Blinks
Lights
Lights for 0.1 seconds. Does not light
for 0.1 seconds. (off for 0.1 seconds)
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
Error lamp
(RED)
Light off
Light off
Indicates
Plugged into power
source
Tool can be used
Adapter cannot be used
due to high temperature.
(Can be used once the
adapter is cooled)
Overload
Cannot be used because
the temperature in the box
is too high
(Can be used once the
box is cooled)