2
Number of daily periods
under the leak threshold
(channel A)
S331
2
Number of daily periods
under the leak threshold
(channel B)
S332
1
Scan period for Channel
A tamper input
S333
1
Tamper detection
threshold channel A
S334
1
Scan period for Channel
B tamper input
S335
1
Tamper detection
threshold channel B
S340
1
Number of redundant
samples per frame
3.4.2

Network registers

The list of registers below allows you to modify the network parameters of the product. This list is ac-
cessible in Provider mode following execution of the ATT63 Provider command.
These registers must be handled with caution because they could cause problems of communication or
of non-compliance with the legislation in force.
Regis-
Size
Description
ter
(bytes)
S201
4
Spreading
Factor (SF) by
default
S202
4
Band width
S205
4
Transmission
power
S206
4
Spreading
Factor (SF)
maximum
S207
4
ADR settings:
ADR_ACK_
LIMIT
Decimal
Default value: 0 (deactivated)
Min/max : 0 to 1440
Unit : none
The multiplication of this register by the period
of flow measurement must be less than 24 hours
otherwise the product will be perpetually in alarm.
Decimal
Default value: 0 (deactivated)
Min/max : 0 to 1440
Unit : none
The multiplication of this register by the period
of flow measurement must be less than 24 hours
otherwise the product will be perpetually in alarm.
Decimal
Default: 2
Min/Max: 1 to 255
Unit: x10 seconds
Decimal
Default: 3
Min/Max: 1 to 255
Unit: none
Number of positive scans of A-channel tamper
before triggering the tamper alarm
Decimal
Default: 2
Min/Max: 1 to 255
Unit: x10 seconds
Decimal
Default: 3
Min/Max: 1 to 255
Unit: none
Number of positive scans of B-channel tamper
before triggering the tamper alarm
Decimal
Default : 0
Min/Max: 0-255
Coding
Decimal
Default: 12 (868) or 10 (915) depending on the reference of the
product
Min/max: 4 to 12
Unit: None
Decimal
Default: 0
Possibilities:
0=125kHz
1=250kHz
2=500kHz
Decimal
Default: 14
Min/max : 2 to 14
Unit : dBm
Decimal
Default: 12 (868) or 10 (915) depending on the reference of the
product
Min/max: 5 to 12
Unit: None
Decimal
Default : 64
Min/max : 1 to 64
Unit: none