Description Of The Registers; Function Register - ADEUNIS ARF8230CA Guide Utilisateur

Masquer les pouces Voir aussi pour ARF8230CA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LoRaWAN 863-870 PULSE - Guide utilisateur / User guide version V3.0.0

3.4. Description of the registers

3.4.1

Function register

The list of registers below allows you to change the behavior of the product application.
Regis-
Size
Description
ter
(bytes)
Transmission period of
S300
N/A
the Keep Alive frame
S301
2
Sending frequency of
the data sensors
S303
1
Confirmed mode acti-
vation
S304
2
PIN code
S306
1
Global operation
S320
1
Channels configuration
(A and B)
S321
2
Historisation period
Coding
Details
Ignored value, the period is set to 24 hours (not
---
configurable) in OPERATION mode
Decimal
Default: 1
Min/max: 0 to 65 535
0 = periodical sending disabled
1: periodical without historisation
X>1 : periodical with X historisations in the frame
Decimal
Default value : 0 (deactivated)
Values : 0 (deactivated) to 1 (activated)
Decimal
Default value : 0 (disabled)
Min/max : 0 to 9999
PIN code used with ATPIN command.
Value 0 disables the PIN code.
IMPORTANT: The PIN code protects the device
configuration. After 3 incorrect attempts the de-
vice is blocked. If blocked, contact the customer
service.
Decimal
Default value: 0
Allows the product to be switched into one of the
following modes:
• 0: PARK mode
• 1: Production mode
• 2 and 3: reserved
Hexadec-
Default value: 0x11
imal
For channel A :
Bit 0 : channel A activation
• Value 0: channel deactivated
• Value 1: channel activated
Bit 1 : meter type channel A (pull-up activa-
tion)
• Value 0: meter other than Gas (pull-up de-
activated)
• Value 1: Gas meter (pull-up activated)
Bit 2 : Reserved
Bit 3 : tamper input channel A
• Value 0: deactivated
• Value 1: activated
For channel B :
Bit 0 : channel B activation
• Value 0: channel deactivated
• Value 1: channel activated
Bit 1 : meter type channel B (pull-up activa-
tion)
• Value 0: meter other than Gas (pull-up de-
activated)
• Value 1: Gas meter (pull-up activated)
Bit 2 : Reserved
Bit 3 : tamper input channel B
• Value 0: deactivated
• Value 1: activated
Decimal
Default value: 43200 (24h)
Unit: x 2 seconds
FR
EN
Page
77
of 103

Publicité

Table des Matières
loading

Table des Matières