Sommaire des Matières pour ADEUNIS LoRaWAN DRY CONTACTS
Page 1
LoRaWAN DRY CONTACTS Transceiver Digital Interface Guide utilisateur / User Guide Version 2.0.0 Ce Guide utilisateur s’applique à partir des versions logicielles suivantes : This User Guide applies from the following firmware versions: Version RTU : V01.04.00 Version APP : V01.03.04 adeunis ®...
Page 2
Ninguna parte de este documento puede ser reproducida o transmitida (en fotocopias electrónico o en papel, o) sin el acuerdo adeunis®. Este documento puede ser modifi cada sin previo aviso. Todas las marcas comer- ciales mencionadas en esta guía son el tema de los derechos de propiedad intelectual.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 TABLE DES MATIERES FRANCAIS INFORMATIONS PRODUITS ET REGLEMENTAIRES PRESENTATION DU PRODUIT 1.1. Description générale 1.2. Encombrement 1.3. Carte électronique 1.4. Spécifications Techniques 1.4.1 Caractéristiques générales 1.4.2 Autonomie 1.4.3 Caractéristiques des interfaces physiques FONCTIONNEMENT DU PRODUIT 2.1.
Page 4
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 ENGLISH PRODUCTS AND REGULATORY INFORMATION PRODUCT PRESENTATION 1.1. General description 1.2. Dimensions 1.3. Electronic board 1.4. Technical Specifications 1.4.1 General characteristics 1.4.2 Autonomy 1.4.3 Physical interface characteristics PRODUCT OPERATION 2.1.
Ce document et l’utilisation de toute information qu’il contient, est soumis à l’acceptation des termes et conditions adeunis®. adeunis® ne donne aucune garantie sur l’exactitude ou l’exhaustivité du contenu de ce document et se réserve le droit d’apporter des modifi cations aux spécifi cations et descriptions de produit à tout moment sans préavis.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 Déclaration UE de Conformité Nous adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Déclarons que la DoC est délivrée sous notre seule responsabilité et fait partie du produit suivant : Modèle produit :...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS ENVIRONNEMENTALES Tous les matériaux d’emballage superfl us ont été supprimés. Nous avons fait notre possible afi n que l’emballage soit facilement séparable en trois types de matériaux : carton (boîte), polystyrène expansible (matériel tampon) et poly- éthylène (sachets, feuille de protection en mousse).
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS D’USAGE • Avant d’utiliser le système, vérifi ez si la tension d’alimentation fi gurant dans son manuel d’utilisation corres- pond à votre source. Dans la négative, consultez votre fournisseur.
Description : • Le LoRaWAN DRY CONTACTS d’adeunis® est un émetteur radio prêt à l’emploi permettant d’une part de reporter des états et des alarmes sur un réseau LoRa et d’autre part de piloter des relais via ce même réseau.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 1.4.3 Caractéristiques des interfaces physiques 1.4.3.01 Interfaces d’entrée digitale Le schéma de principe des interfaces d’entrée digitale est le suivant : Valeurs absolues maximales Unité Tension minimale d’entrée - 0,7 Tension maximale d’entrée...
Page 15
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 Caractéristiques électriques Unité Tension de charge minimale Tension de charge maximale Courant dissipé maximum recommandé Fréquence de sortie maximale Consommation de courant niveau de sortie HAUT µA Consommation de courant niveau de sortie BAS µA...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2. FONCTIONNEMENT DU PRODUIT 2.1. Modes de fonctionnement NOTE IMPORTANTE : adeunis® utilise le format de données Big-Endian Le produit dispose de plusieurs modes de fonctionnement : MODE PARC Présence d’un aimant...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.1.4 Mode REPLI Le produit entre dans ce mode très basse consommation suite à la détection d’un niveau de batterie trop faible. Dans ce mode le produit se réveille toutes les 5 secondes pour faire clignoter 2 fois la LED rouge.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.2.2 Transmission périodique Le produit permet le comptage et la transmission périodique des évènements survenus sur les entrées selon le schéma suivant : Produit en veille Changement Période sur entrée...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.2.3 Fonctionnement des compteurs Les compteurs représentent selon la configuration, le nombre de fronts hauts et bas, bas uniquement ou hauts uniquement. Ils sont codés sur 2 octets donc limités à une valeur de 65 535, l’utilisateur doit donc être vigilant sur la périodicité d’envoi afin de ne pas dépasser 65 535 évènements entre deux émissions.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.2.4 Commande de sortie(s) du produit Le produit permet de configurer tout ou une partie des TORs en sortie afin de piloter celles-ci depuis le réseau par une trame descendante (downlink) selon le schéma suivant :...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.2.5 Transmission d’une trame de vie journalière En mode évènementiel uniquement, le produit pourrait ne jamais envoyer de trames de données. Ainsi, pour s’assurer du bon fonctionnement de celui-ci une trame de vie est transmise régulièrement selon le schéma suivant : Produit en veille Si l’une des entrées est en mode périodique il n’y a pas...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.3. Fonctionnement des LEDs Mode Etat Led Rouge Etat Led Verte Emission de trame (mode TEST seulement) Allumé pendant l’émission Réception de trame (mode TEST seulement) Allumé pendant la réception d’une trame de...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 CONFIGURATION DU PRODUIT La configuration du produit se fait au moyen du connecteur USB. Cette connexion permet de communiquer avec le produit par un port com virtuel et d’envoyer des commandes AT pour modifier les paramètres du produit.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 3.2. Mode commande Utiliser un terminal port COM pour communiquer avec le produit. Nous utilisons le soft terminal port COM HERCULES disponible en télécharge- ment gratuit à l’adresse suivante : http://www.hw-group.com/products/hercules/index_en.html...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 3.3. Commande AT Une commande débute avec les 2 caractères ASCII : « AT », suivis d’un ou plusieurs caractères et données (voir ci-après la syntaxe des com- mandes AT disponibles sur le modem).
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 3.4. Description des registres A la mise sous tension le produit fonctionne selon la dernière configuration sauvegardée (configuration usine si c’est la première mise sous tension, ou si cette configuration n’a pas été changée).
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 Configuration de l’entrée TOR1 Hexadécimal Défaut : 0x46 Bits 0 à 3 : Type • 0 = Désactivée • 1 = Entrée - Mode périodique – Front haut • 2 = Entrée - Mode périodique – Front bas •...
Page 28
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 LORA APP-KEY (première partie – MSB) Hexadécimal Défaut : 0 Clé codée sur 32 caractères octets. Chacun des 4 registres LORA APP-KEY (deuxième partie – MID MSB) Hexadécimal contient 8 caractères.
Page 29
• NWK_sKEY Clé de session réseau (Par défaut : fourni par adeunis®) • APP_sKEY Clé de session applicative (Par défaut : fourni par adeunis®) • DEVICE ADDRESS Adresse du device dans le réseau (Par défaut : fourni par adeunis®) NOTE 2 : Par défaut, les canaux 0 à...
Page 30
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 SF12 SF11 SF10 SF7 – BW 250kHz FSK 50 kps L’exemple donné permet de configurer une fréquence de 868.1 Hz et autorise un SF de 7 à 9. La commande à envoyer pour réaliser cette opéra- tion est : ATS250=86810053<cr>...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4. DESCRIPTION DES TRAMES 4.1. Trames montantes (uplink) Toutes les trames montantes du produit vers le réseau (uplink) ont toujours une taille de 11 octets. 4.1.1 Octets fixes Les deux premiers octets de la trame sont systématiquement dédiés pour indiquer le code de la trame et le statut comme présenté ci-dessous :...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4.1.2 Trames d’information sur la configuration du produit Suite à la réception d’une trame descendante (downlink) avec le code 0x01 ou lors du passage en mode exploitation (sortie du mode PARC ou COMMANDE), les trames suivantes (0x10) représentant la configuration applicative du produit sont transmises :...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4.1.3 Trame d’information sur la configuration du réseau Suite à la réception d’une trame descendante (downlink) avec le code 0x02 ou lors du passage en mode exploitation (sortie du mode PARC ou COMMANDE), la trame suivante (0x20) représentant la configuration réseau du produit est transmise :...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4.1.6 Trame de données Cette trame (0x40) contient les valeurs relevées sur les différents TOR. Code Status PAYLOAD 0x40 Cf Status Informations TOR1 Informations TOR2 Informations TOR3 Informations TOR4 Détails...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4.1.7 Synthèse des conditions d’envoi des trames montantes Le tableau ci-après résume les conditions d’envoi des différentes trames montantes : Code Description Scenarii d’envoi 0x10 Trames d’information sur la configuration •...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4.2.3 Trame de pilotage des sorties Cette trame permet de faire changer d’état les TORs configurés en sortie. Code PAYLOAD 0x03 Etats des sorties 0x03 0x05 Description de la trame : •...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4.2.4 Trame de demande de valeur de registres spécifiques Cette trame (0x40) permet de faire savoir au produit via le réseau qu’il doit émettre les valeurs des registres demandés.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 5. PREPARATION ET DEMARRAGE 5.1. Description des câbles Zoom sur les câbles : TOR A TOR B TOR C TOR D 5.2. Exemple de câblage en entrée L’exemple suivant montre le câblage à réaliser pour récupérer en entrée l’état ouvert ou fermé du capteur 1 :...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 5.3. Exemple de câblage en sortie Les sorties du produit DRY CONTACT peuvent être configurées en sortie pour piloter des équipements. Les sorties sont des sorties collecteur ouvert. Il est donc nécessaire d’ajouter un relais en sortie pour piloter des équipements, le produit n’étant pas capable de fournir directement une tension en sortie du produit.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 5.4. Démarrage du produit via aimant Une fois la configuration du produit effectuée et son montage finalisé, le produit est prêt à être démarré. Le démarrage s’effectue à l’aide d’un aimant que l’on appose sur la partie haute du produit (cf schéma ci-dessous). L’aimant doit être maintenu en position au minimum 6 secondes de sorte à...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 Fermeture du boîtier : Procédure : Assurez-vous que le joint d’étanchéité est bien en place sur la semelle Clipser la carte électronique sur la semelle du boîtier. Assurer-vous que le clip de fixation est bien enclenché dans l’ergot de la carte.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 6. INSTALLATION ET UTILISATION 6.1. Positionnement correct des émetteurs Deux règles sont primordiales pour une optimisation des portées radio. • La première consiste à positionner votre produit le plus haut possible.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 Pour retirer celui-ci, tirer vers le bas sur le levier jusqu’à ce que les ergots de blocage soient face à une partie dégagée et retirer le levier Ergots Partie dégagée 6.2.2 Fixation par vis...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 6.2.3 Fixation Rail-DIN Ce système, intégré au boîtier, permet de fixer le produit sur un rail standard de 35mm • Pour installer le boîtier, placer les inserts supérieurs sur le rail et abaisser le produit pour le clipser •...
Version APP : V01.03.04 DISCLAIMER This document and the use of any information contained therein, is subject to the acceptance of the adeunis® terms and conditions. They can be downloaded from www.adeunis.com. adeunis® makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifi...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 EU Declaration of Conformity adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Declare that the DoC is issued under our sole responsibility and belongs to the following product:...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 ENVIRONMENTAL RECOMMENDATIONS All superfl uous packaging materials have been eliminated. We have done everything possible to make it easy to separate the packaging into three types of materials: cardboard (box), expanded polystyrene (fi ller material) and polyethylene (packets, foam protective sheets).
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS REGARDING USE • Before using the system, check that the power supply voltage shown in the user manual corresponds to your supply. If it doesn’t, please consult your supplier.
IMPORTANT NOTE: The LoRaWAN DRY CONTACTS can only be started with a magnet. Description: • The adeunis® LoRaWAN DRY CONTACTS is a ready-to-use radio transmitter enabling the user on one hand to transfer statuses and alarms on a LoRa network and on the other to control relays via the same network.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 1.4. Technical Specifications 1.4.1 General characteristics Parameters Value Supply voltage Nominal 3.6V Power supply: Removable battery version: SAFT LS14500 Maximum power 90mA Working temperature -25°C / +70°C Dimensions: 105 x 50 x 27mm...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 1.4.3 Physical interface characteristics 1.4.3.01 Digital input interfaces The schematic diagram of the digital input interfaces is the following: Absolute maximum values Units Minimum input current - 0,7 Maximum input current Electrical characteristics Unité...
Page 55
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 Absolute maximum values Units Minimum charging voltage -0,7 Maximum charging voltage Maximum dissipation current (DC) Electrical characteristics Units Minimum charging voltage Maximum charging voltage Maximum recommended dissipation current Maximum output frequency Current consumption at high output µA...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2. PRODUCT OPERATION 2.1. Global operation Important: adeunis® use the most significant byte first format. The product has several operating modes: PARK MODE Presence of a magnet on the product >6s...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.1.4 REPLI mode The product enters this very low consumption mode following the detection of a level of battery that is too low. In this mode the product wakes up every 5 seconds to make the red LED flash twice.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.2.2 Periodic transmission The product allows the measurement and the periodic transmission of the values of the sensors according to the following diagram: Product in standby Change on Period...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.2.3 Operation of the counters The counters represent, depending on the configuration, the number of high and low, low only or high only edges. They are coded on 2 bytes therefore limited to a value of 65,535 the user must therefore be vigilant on the periodicity of sending in order not to exceed 65,535 events between two transmissions.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.2.4 Control of the product output(s) The product allows you to configure all or a part of the digital connections as outputs to control them from the network by a downlink frame...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.2.5 Transmission of a daily Keep Alive frame In the event mode only, it is possible that the product would never send data frames. So to be sure that it is working properly a Keep Alive frame...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 2.3. Operation of the LEDs Mode LED red state LED green state Transmission of frame (TEST mode only) ON during the transmission cycle Reception of frame (TEST mode only)
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 DEVICE CONFIGURATION The device can be configured using the USB connector. This connection allows you to communicate with the device via a virtual com port and to transmit AT commands in order to modify the parameters of the device.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 3.2. Command mode Use a COM port terminal in order to communicate with the device. We use the HERCULES COM port soft terminal available to download for free by clicking on the following link: http://www.hw-group.com/devices/hercules/index_en.html •...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 3.3. AT Commands A command starts with 2 ASCII characters: “AT”, followed by one or more characters and data (see the list below for the syntax of AT com- mands available on the modem).
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 3.4. Description of the registers On switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configuration has not been changed).
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 Input TOR1 configuration: Hexadecimal Default : 0x46 Bits 0 to 3: Type • 0 = Disabled • 1 = Input - Periodic Mode - High edge • 2 = Input - Periodic Mode - Low edge •...
Page 68
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 LORA APP-KEY (first part – MSB) Hexadecimal Default: 0 Key encoded on 32 byte characters. Each of the 4 registers LORA APP-KEY (second part – MID MSB) Hexadecimal contains 8 characters.
Page 69
• NWK_sKEY network session key (provided by default by adeunis®) • APP_sKEY applicative session key (provided by default by adeunis®) • DEVICE ADDRESS Address of the device in the network (provided by default by adeunis®) NOTE 2: By default, channels 0 to 2 use the default settings of the LoRaWAN network; the other 4 channels are inactive. A register value different from 0...
Page 70
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 Data Rate value (DR) Description SF12 SF11 SF10 SF7 – BW 250kHz FSK 50 kps The example given allows the user to configure a frequency of 868.1 Hz and authorizes a SF 7 to 9. The command to be sent to perform this operation is: ATS250=86810053<cr>...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4. DESCRIPTION OF THE FRAMES 4.1. Uplink frames All of the uplink frames of the product to the network (uplink) always have a size of 11 bytes. 4.1.1 Fixed bytes...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 E.g.: A value of the status byte equal to 0xAB (= 10101011 in binary) gives: • Bit 7 at 5 = 101 = 0x05 i.e. a frame counter at 5 •...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4.1.3 Network configuration data frames Following reception of a downlink frame with the code 0x02 or on switching to the operating mode (from the Park or Command Mode), the...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4.1.6 Data Frame This frame (0x40) contains the values measured on the different digital outputs. Code Status PAYLOAD 0x40 Cf Status Informations TOR1 Informations TOR2 Informations TOR3 Informations TOR4...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 4.1.7 Summary of the conditions of transmission of uplink frames The table below summarizes the conditions of the transmission of the different uplink frames: Code Description Sending conditions 0x10 Product configuration data frames •...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 Description of the frame: • Byte 1: States to be applied to the TORs • Bit 0: State to be applied to TOR1 • Bit 1: State to be applied to TOR2 •...
Page 77
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 Description of the frame : • Byte 1: CONFID1 (8bits) : indice of the first register to change. The corresponding register is 300 + value of CONFIDX. For example, if CONFID1 = 20, the product will change the value of register number 320.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 5. PREPARATION AND START-UP 5.1. Cable description Zoom on the cables: TOR A TOR B TOR C TOR D 5.2. Example of Input Wiring The following example shows the wiring to be performed to recover the open or closed state of the sensor 1:...
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 5.3. Example of output wiring The Dry Contact product outputs can be configured as outputs for controlling the equipment. The outputs are open collector outputs. It is therefore necessary to add an output relay to control equipment as the product is not able to provide a product output voltage directly.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 5.4. Starting up the product using a magnet Once the product has been configured and its assembly has been finalised, the product is ready to be started up. The start-up is carried out using a magnet which you place on the upper part of the product (cf. the diagram below). The magnet must be held in position for at least 6 seconds so as to confirm the start-up of the product.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 5.6. Closing the casing Once previous stages have been carried out, you can close the casing of the LoRaWAN DRY CONTACTS Procedure: Make sure that the seal is properly positioned on the base Clip the electronic board onto the casing’s base.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 6. INSTALLATION AND USE 6.1. Correct positioning of the product transceivers There are two key rules for optimising radio ranges. • The first one consists of positioning your product as high as possible.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 To optimise fastening onto a tube or mast, we recommend you Pins remove the Rail-DIN locking/unlocking lever. To remove it, pull the lever down until the locking pins are opposite Freed up part a freed-up part and then remove the lever.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 6.2.3 DIN-Rail fixing This system, integrated into the casing, enables the product to be fastened onto a standard 35 mm rail. • To fit the casing, place the upper inserts on the rail and lower the product to clip it into position.
Recht vor, jederzeit und ohne Vorankündigung Änderungen an den Produktspezifi kationen und -beschreibungen vorzunehmen. adeunis® behält sich alle Rechte an diesem Dokument und den darin enthaltenen Informationen vor. Die Ver- vielfältigung, Nutzung oder Weiterverbreitung an Dritte ohne ausdrückliche Genehmigung ist streng untersagt.
Page 87
Programmiersprachen, unter Verwendung jeglicher elektrischer, mechanischer, magnetischer, optischer, manueller Geräte oder anderer Methoden, ist untersagt. adeunis® behält sich das Recht vor, ohne schriftliche Bekanntgabe und ohne ausdrückliches Verlangen seiner Kun- den die technischen Spezifi kationen oder Funktionen seiner Produkte zu ändern und sicherzustellen, dass die ihnen zur Verfügung gestellten Informationen gültig sind.
Page 88
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 UMWELTSCHUTZHINWEISE Es wurden alle überfl üssigen Verpackungsmaterialien vermieden. Wir haben uns bemüht, dass die Verpackung leicht in drei Materialarten getrennt werden kann: Pappe (Schachtel), expandiertes Polystyrol (Puff ermaterial) und Polyethylen (Tüten, Schaumstoff -Schutzlage). Ihr Gerät besteht aus recycelbaren Materialien, die im Falle einer Demontage durch ein Fachunternehmen wiederverwendet werden können.
LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0 GEBRAUCHSHINWEISE • Überprüfen Sie vor Benutzung des Systems, ob die in dessen Betriebsanleitung angegebene Versorgungsspan- nung mit Ihrer Stromquelle übereinstimmt. Falls nicht, wenden Sie sich an Ihren Lieferanten. •...