LoRaWAN 863-870 Pulse - Guide utilisateur / User guide version V2.0.0
4.1.10
Summary of the conditions of the transmission of the uplink frames
The table below summarizes the conditions of the transmission of the different uplink frames:
Code
0x10
Product configuration data
frames
FR
0x20
Frames of information on
the network configuration
0x30
Keep Alive frame
EN
0x31
Reply frame to a register
value request
0x46
Data Frame
0x47
Alarm frame
0x48
Periodic frame with 1
hour-history
0x48
Periodic frame with 24
(x3)
hours-history
Description
• Start-up of the product
• Exit from the configuration mode
• Reception of a downlink frame 0x01
• Periodically if the inputs are deactivated (period defined by register
S301)
• Start-up of the product
• Exit from the configuration mode
• Reception of a downlink frame 0x02
24 hours elapse since the start-up of the product or since the last trans-
mission of this frame (5 minutes in TEST mode)
• Reception of a downlink frame 0x40
•
•
•
Exceeded flow threshold on one of the two channels (sending only if the
exceeded flow control is enabled by writing a non-zero value in the S326
or S327 registers).
1 hour elapses since the start-up of the product or since the last trans-
mission of this frame
This frame is sent only if the history feature is activated in register S321.
24 hours elapse since the start-up of the product or since the last trans-
mission of this frame
This frame is sent only if the history feature is activated in register S321.
Sending conditions
Start-up of the product (RUN mode).
Exit from the configuration mode (AT command)
Transmission period reached (period defined by register S301)
Page
94
of 108