LoRaWAN 863-870 Pulse - Guide utilisateur / User guide version V2.0.0
Example :
Register
Value encoding
S320
Hexadecimal
FR
S321
Hexadecimal
S322
Hexadecimal
EN
S325
Decimal
S328
Decimal
S329
Decimal
S330
Decimal
S331
Decimal
In this example, all the periods during which the flow rate on the channel A is less than 10 pulses /
hour are considered as periods of zero flow. If the total daily number of zero flow periods is less than 3
then it is considered that there is a leak on the channel A.
2.2.7
Mode TEST
This mode allows the user to perform tests of the product more quickly by reducing the time scales of
the production mode and modifying the behavior of the LEDs.
It is obtained by positioning register S306 at the value 2 in the COMMAND mode. Once out of the com-
mand mode, the product returns to the previously defined application behavior but with the following
changes:
-
Register S300: the periodicity of the Keep Alive is expressed in groups of 5 minutes instead of
24 hours.
-
Register S301: the periodicity of the sending of data (periodic mode) is expressed in groups of
twenty seconds instead of minutes. Hence in test mode when register 301 = 1, the Keep Alive frame is
no longer sent every 1min but every 20 seconds.
-
Register S325 : the flow calculation period (channels A and B) is expressed in twenty seconds
slots instead of minutes. So in TEST mode when the register 325 is set to 60, the flow calculation peri-
od (channels A and B) is 60x20s=1200s (so 20min) instead of 60 minutes.
-
The LEDS also have a different behavior, allowing a visual feedback to the user in the event of
transmission and reception of frames (see paragraph 2.3 for more details).
A complete list of the registers can be found in paragraph 3.4.
E.g.:
Regis-
Coding the value
ter
S306
Decimal
S300
Decimal
S301
Decimal
Decimal
S325
Value
Result
0x39
Channel A :
•
Activated
•
Meter other than gas
•
Tamper input activated
Channel B :
•
Activated
•
Gas meter
•
Tamper input disabled
0x02
Channels A and B : historical mode with backup of the counters
every hour and transmission every 24h so 24 values per counter
0x57
Anti-bounce :
•
Channel A = 500ms
•
Channel B = 100ms
60
Flow calculation period (channels A and B) = 60min
10
Leak threshold (channel A) = 10 pulses par hour
0
Leak threshold (channel B) = 0 pulse par hour
Daily periods number under the leak threshold (channel A)
3
= 3
5
Daily periods number under the leak threshold (channel B)
= 5
Value
Result
2
The product is in TEST mode
--
The Keep Alive frame is sent every 5 minutes
1
Periodic mode with a period of 1x20 = 20s
60
Flow calculation period (channels A and B) is
60x20s=1200s ie 20 minutes
Page
74