History configuration
(channels A and B)
Anti-bounce filter period
(pulse minimum width)
(channels A and B)
Current value of meter -
channel A
Current value of meter -
channel B
Flow calculation period
(channels A and B)
Flow threshold (channel
A)
Flow threshold (channel
B)
Leak threshold (channel
A)
Hexadec-
Default value : 0x00
imal
Bits 0 to 2: History configuration
Value 0: no history
Value 1: history period set to 10min / trans-
mit period set to 1 hour
Value 2: history period set to 1 hour / trans-
mit period set to 24 hours
Hexadec-
Default value: 0x22
imal
Bits 0 to 3 : anti-bounce filter period - channel A
Value 0: deactivated
Value 1: 1 ms
Value 2: 10 ms
Value 3: 20 ms
Value 4: 50 ms
Value 5: 100 ms
Value 6: 200 ms
Value 7: 500 ms
Value 8: 1 s
Value 9: 2 s
Value A: 5 s
Value B: 10 s
Value C à F : reserved
Bits 4 to 7 : anti-bounce filter period - channel B
Value 0: deactivated
Value 1: 1 ms
Value 2: 10 ms
Value 3: 20 ms
Value 4: 50 ms
Value 5: 100 ms
Value 6: 200 ms
Value 7: 500 ms
Value 8: 1 s
Value 9: 2 s
Value A: 5 s
Value B: 10 s
Value C à F : reserved
Decimal
Default value: 0
Min/max : 0 to (2
Unit : number of pulses
In COMMAND mode, it is possible to write a new
value in this register (for example an initialization
value, an adjustment value ...).
Decimal
Default value: 0
Min/max : 0 to (2
Unit : number of pulses
In COMMAND mode, it is possible to write a new
value in this register (for example an initialization
value, an adjustment value ...).
Decimal
Default value: 60
Min/max : 1 to 1440
Unit :
x 1min if S306=1
x 20s if S306=2
Decimal
Default value :0 (deactivated)
Min/max : 0 to 65535
Unit: pulses per hour
Decimal
Default value :0 (deactivated)
Min/max : 0 to 65535
Unit: pulses per hour
Decimal
Default value: 0
Min/max : 0 to 65535
Unit : pulses per hour
)