Measurement Of Voltage Frequency; Measurement Of Ac Current Frequency - Metrix MX 670 Notice De Fonctionnement

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
4.7

Measurement of voltage frequency

Position the switch on V
and press the DISPLAY key.
Connect the red test lead to
the "+" terminal and the black
test
terminal.
Place the touch prods in
contact with the points whose
frequency is to be measured.
Read the frequency value on
the secondary display.
The main display indicates the
4.8

Measurement of AC current frequency

Position the switch on A
press
Open the jaws by pressing the
trigger. Position the clamp around
the conductor to be measured.
Release the trigger. Check that
the clamp is properly closed. Read
R
the result of the measurement on
the secondary display.
The main display indicates the
value of the measured TRMS
current.
1000
30
,
lead
to
the
"COM"
value of the measured TRMS
voltage.
, and
the
DISPLAY
key.
MX670 / MX675

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mx 675

Table des Matières