Compact probes KFX-5-... / KFX-4-...
Technical data
Active zone (mm)
Electrical version
Output
Type NPN
Type PNP
Operating voltage (U
B
Output current max. (I
Voltage drop max. (U
Permitted ripple max.
Switching frequency max.
No-load current (I
)
o
Permitted ambient temperature
Permitted ambient temperature (for active zone)
Pressure stainless steel
Pressure Aluminium
LED-Display
Protective circuit
Norm
Degree of protection IEC 60529
Connection
Housing material
Active zone
Certificates
Dimension No. 3
Connection head VA:
X = Length 100, 200,...1000 mm
Y = Process connection
)
)
e
)
d
Type specific
4 terminals, DC
1 point probe = antivalent / 2 point probe = NO or NC
KFX-...-N-...
KFX-...-P-...
18...36 V DC
2 x 250 mA
Typ. 50 mA
-25...+55 °C
-25...+100 °C
Green / yellow
EN 60947-5-2
Terminal block at wiring space
Type specific
Type specific
Dimension No. 4
Connection head AL:
≤ 2.5 V
40 %
4 Hz
25 bar
6 bar
Built-in
IP 67
CE, RoHS
25