List of parameters and Factory stored programs
List of parameters and Factory Configuration program:
Parameter
Preflow
Start Current
Upslope
Set Current
Duty Cycle
Frequency (f)
Background
Downslope
Crater
Postflow
Stick Welding: SOFT and CRISP programs
Parameter
Hot start, Anti-Sticking and Arc Force are
Soft Stick
automatically adjusted by the machine
Hot start, Anti-Sticking and Arc Force are
Crisp Stick
automatically adjusted by the machine
TIG SPOT WELDING (to previously enable with option 10 in Setup menu)
Parameter
Spot Current
English
Factory Configuration
(P99)
0.1s
Lift TIG 2-step: 22A
Lift TIG 4-step: 100%
HF TIG 2-step: 100%
HF TIG 4-step: 100%
0.5s
5A
50%
0.1Hz
30%
0s
30%
10s
Features
Features
Trigger = 2-step
No restart function enabled
Preflow time = 0s
Upslope time = 0s
Downslope time = 0s
Postflow time = 0s
Selectable Value Range
0 - 5s (step 0.1s)
Not adjustable
5 - 200%
0 - 5s (step 0.1s)
5 - 270A (Stick) (315DC)
5 - 300A (TIG) (315DC)
5 - 400A (415DC)
10 - 90% (step 5%)
(f>300Hz Duty=50% 315DC)
(f>200Hz Duty=50% 415DC)
0.1 - 10Hz (step 0.1Hz)
10 - 300Hz (step 1Hz)
300 - 500Hz (step 10Hz)
10 - 90% (step 1%)
0 - 20s (step 0.1s)
5 - 100%
0 - 30s (step 1s)
Selectable Value Range
Set Current
With SOFT / CRISP Stick,
this is the unique parameter
adjustable by the user.
Selectable Value Range
5 - 300A (315DC)
5 - 400A (415DC)
14
Displayed
parameter
Displayed
name
value
Current
selected value
(s)
Current
selected value
(A)
Current
selected value
(s)
Current
Voltage at
selected value
output studs
(A)
Current
selected value
(%)
Current
selected value
(Hz)
Current
selected value
(%)
Current
selected value
(s)
Current
selected value
(A)
Current
selected value
(s)
Displayed
parameter
Displayed
name
value
Current
selected value
(A)
Current
selected value
(A)
Displayed
parameter
Displayed
name
value
Current
Voltage at
selected value
output studs
(A)
English