Technical Specifications; Dimensions; Circuit Diagram For Jetstream Trevi, Trevi Lux; With Single-Phase Motor (Trevi 230 V) - UWE JetSTREAM TREVI Traduction Des Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8

TECHNICAL SPECIFICATIONS

Model(s) JetStream TREVI/TREVI LUX Typ 8203/2a/2aL
JetStream TREVI/TREVI LUX Typ 8203/7a/7aL
Characteristics:
8203/7a/7aL
Power supply:
-
Nominal voltage:
230 V AC
Rated frequency:
50 Hz
Rated input:
1,7 kW
Protection class:
I
Protection:
IP 55
Pump unit:
Nominal voltage:
230 V AC
Rated frequency:
50 Hz
Rated input:
1,7 kW
Current Rating:
7,9 A
Flow rate:
650 l / min.
Head:
18m
Floodlights:
Nominal voltage:
12V AC 50Hz SELV
Rated input:
120 W
Protection class:
III
8.1
Dimensions: (230 V / 400 V)
Measurements in mm
fixing screw
with plug
water-
level
nozzle
8203/2a2aL
-
400 V 3N AC
50 Hz
2,5 kW
I
IP 55
400 V 3N AC
50 Hz
2,5 kW
4,3 A
720 l / min.
19m
12V AC 50Hz SELV
120 W
III
special
version:
insert of
cable from below
insert of
(empty pipe)
cable
(standard
version)
gum buffer
9
CIRCUIT DIAGRAM FOR JETSTREAM TREVI,
TREVI LUX
9.1 With Single Phase Motor (TREVI 230 V)
Mains 1 N 230 V AC 50 Hz
circuitbreaker
Cable type
board
control
Circuit
T 0,8 A
Reed-
switch
PE-
converter
T-hose
Plug-in
connector
inductor
Low
Pumping set
pressure
cable
Pneumaticswitch
9.2 with Pneumaticswitch Mains 3 N 400 V 50 Hz
circuitbreaker
Cable-type
board
control
Circuit
T 0,8 A
Reed-
switch
PE-
converter
T-hose
Plug-in
connector
inductor
Low
pressure
Pumping set
cable
Pneumaticswitch
17
Fuse T 16 A
Mains switch (Disconnector)
Outlet box
F2 Circuit
T 0,8 A
Cable type
Floodlight
12 V 100 W
Pneumatic-
switch
Fuse T 16 A
(inert) or. K-resp.
G - automat 6 A
Mains switch
(Disconnector)
Outlet box
F2 Circuit
T 0,8 A
Cable
type
Floodlight
12 V 100 W
Pneumaticswitch

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Jetstream trevi lux

Table des Matières