5.2
Direction of Rotation (TREVI 400 V only)
If your motor has the correct direction of rotation (see arrow on the motor), the pump runs quietly and, with the nozzle open, the flow velocity at 2 m in front
of the nozzle opening is approx. 1.2 m/s. If the motor is running in the wrong direction, the pump will be very loud and little or no water is pumped.
Attention Dangerous voltage!
To change the direction of rotation, ask your electrician to switch two phases at the mains supply.
Before you turn the unit on again, remove the cover (5), unscrew the screw plug (8) and fill the pump with water. Replace the screw plug and cover.
6

SETTING INTO OPERATION

6.1

Before Setting into Operation

The safety instructions must be read carefully before setting into operation.
6.2

Setting the Unit into Operation for the First Time

You must definitely fulfil the requirements stated by the uwe company and by the standard authorities. If the instructions are not observed, the installation
engineer shall bear the sole responsibility. The manufacturer shall thus be absolved of any liability.
Instructions to the user:
Do not take any defective equipment into operation.
Fix safety instructions clearly visible.
Hold the instructions ready.
Water temperature up to 35 ° C.
The unit must not be operated without water.
The unit must not be used as a starting block.
The unit must only be placed into operation while it's in the water.
Switch on the unit.
Check the direction of rotation (with TREVI 400 V).
7

MAINTENANCE

7.1
Exchanging the Lamp (TREVI LUX only)
Attention Dangerous voltage!
Unplug the unit from the mains!
Unscrew both countersunk screws M 8 x 60 from the ring of the lamp housing which secures the shade. Remove the lamp housing by pulling it forwards.
Turn the lamp housing so that the cable wrapped around the lamp housing unwinds allowing you to lift the lamp housing above the surface of the water.
Here, remove the straining ring and pull out the lamp housing. Remove the 4 tapping screws with countersunk heads from the cover of the housing and
then unscrew the lamp connections at the ceramic luster terminals.
Unscrew the lamp connections from the lamp and exchange the lamp.
When reassembling the lamp, ensure you fit the new rubber washer supplied with the lamp between the housing cover and housing and that you wind the
cable around the lamp housing again. Fit the whole lamp unit back into the unit.
7.2

Damaged power line

Attention hazardous voltage!
If the mains cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid
hazards.
7.3

Cleaning

Clean external surfaces of the unit when necessary with a damp cloth. The water used to wet the cloth may contain some detergent.
Do not use abrasive cleaning agents!
7.4

Replacement parts

It may be used only original spare parts or parts which meet the specifications of the company uwe JetStream GmbH.
A detailed list of spare parts is available from uwe JetStream GmbH upon request.
7.5

Lifetime

During operation of the pump in accordance with the instructions in this guide, you will have many years of enjoyment from this system.