Further Installation
Secure the unit together with the rubber buffer (4) to the pool wall.
The gap between the pool wall and the back of the housing submerged in the water must be at least 25 mm and a maximum
of 80 mm.
Unscrew the retention screw (11) for the support (10) and slide the support out until it stands on the floor when the unit is in a horizontal position.
Secure the support to the ground. If the ground under the support is loose, lay a flag stone underneath the support (small concrete foundation).
Fit the retention pin (1) on the edge of the pool and tighten.
Unscrew the screw plug (8). Slowly fill the pump with water.
When the pump is full (volume approx. 8.5 l) water does not overflow but flows back into the swimming pool through the nozzle.
Screw in the screw plug (8) and washer and screw tight.
Fit the cover (5) (supplied separately). On the inside of the cover there is a holding band (15). Pull the free end of the holding band through, under the
pressure plate (14) which is on the base plate. Screw in both the Phillips screws of the pressure plate.
The cover must be fastened securely to the base plate via the holding band. Secure the cover (5) using the four fastening screws (13).
The unit has a safety switch and can be started only once the cover (5) has been fitted.
If the pump fails to pump water after the first attempt to start it, you must re-fill the pump with water (there is still air in the pump
housing). You must continue to fill the pump until the nozzle has its full power.
4
5

ELECTRIC CONNECTION

5.1
Electric Connection
Attention!
All work on stationary swimming pool pumps must only be performed by companies authorised by uwe and by trained electrici-
ans. The DIN VDE and applicable regulations for the prevention of accidents must be observed for all work with voltages.
The unit is shipped with an 8 m (TREVI 230 V) or 10 m (TREVI 400 V) long, weather-resistant power supply cable and outlet box. For the power supply to
the permanent connection, a cable cross-section of 3 G 2.5 mm2 (L,N,PE) for TREVI 230 V and H07 5 G 2.5 mm2 for TREVI 400 V is required,
respectively. The unit must be protected against shock with protective earthing DIN VDE 0100 Part 702 and by connecting a circuit-breaker FI>=30 mA.
In the protection zone 0 and 1 to DIN VDE, the connecting cable must be laid in a plastic pipe or directly in the walkway behind the pool wall.
The powerful single-phase motor (TREVI 230 V) or three-phase motor (TREVI 400V) is secured below the cover which is mounted on the edge of the pool.
This motor is separated from the water-guiding parts of the pump. All foreign conductive parts in the areas 0.1 and 2 must be included in the additional,
local equipotential bonding.
This additional, local equipotential bonding must be connected to the PE conductors of the bodies in these areas. In addition,
please refer to the „Information for the Electrician".
Picture 4
Attention!
Before placing into operation (1), plug in the strap (2)
from the cover (3) into the safety switch (4) (see arrow)!